Service manual

17
in.xe
Heat.wav heater
In.xe comes with a high
performance heat.wav heater.
With no pressure switch, it
features in. o integrated dry-
re protection.
The heat.wav heater is factory con gured 240v /4 kW (or
2KW), but it can be converted to a dedicated 120v / 1kW by a
simple switching a cable connection port. (Option available on
NorthAmerican models only).
Heat.wav specifi cation summary:
Supports 120v or 240v
Protected by external
breaker (not fused)*
Incolo or Titanium (optional) heater element
for greater protection against corrosion.
Connections for 120v
heater (1KW)
L1 GroundN L2
Connections for 230/240
VAC heater (4KW or 2 KW)
Heater connections
Note: European models are 230 or 240 VAC and are fuse protected
A watertight panel protects the
heater and probe connectors.
Removing the panel gives
access to in.fl o dry- re
protection and
hi-limit/regulation probe
connectors, line 1, line 2 and
ground power input cables
connection ports.