Service manual

41
in.xe
HL Probe & Temp Probe
HL
Water temperature at the
heater has reached 11F
1• Measure the temperature
with a DIGITAL thermo-
meter and compare its
reading with temp. on the
display. Make sure the temp.
reading is lower than 119°F.
3• If reading is 11F or higher:
Verify if the Temp. & High
Limit probes are properly
connected.
Shut power off and power
the spa up again to reset
the system.
If problem persists,
replace heater.
If problem persists,
replace Spa Pack.
HL error condition step-by-step
2• If reading is below 119°F:
a- Check if heater barrel
feels hot. If it’s hot, verify
if anything is obstructing
water ow (closed valves
or dirty lter).
b- Shut power off and
power the spa up again
to reset the system.
c- If HL error condition
persists, replace heater.
d- If HL error condition
persists, replace Spa Pack.