Service manual

49
in.xe
"Pump 1 doesn't work" step-by-step
Pump up to 15 Amp :
240 VAC: Pin 2 & Pin 1
120 VAC: Pin 2 & Pin 5
Your reading shoud be:
240 VAC for a 240 VAC pump
120 VAC for a 120 VAC pump
Pump 1 fuse
Turn Pump 1 to low speed
and take voltage reading
between:
240 VAC: Pin 6 & Pin 1
120 VAC: Pin 6 & Pin 5
Your reading shoud be:
240 VAC for a 240 VAC pump
120 VAC for a 120 VAC pump
120 VAC at P1 connector:
Pin 3 & Pin 5
240 VAC at P1 connector:
Pin 3 & Pin 1
240 VAC
at P1 connector:
240 VAC at P1 connector: 240 VAC
120 VAC
at P1 connector:
120 VAC at P1 connector: 120 VAC
Pin 5
120VAC at P1 connector:
Pin 6 & Pin 5
240 VAC at P1 connector:
Pin 6 & Pin 1
240 VAC at P1 connector:
Pin 1
120VAC at P1 connector:
Pin 5
Pin 3
Pin 1
Pin 3
Pin 6
Pin 6
If Pump 1 does not work in
either speed, replace Pump
1 fuse.
If replacing the fuse is not
effective or if Pump 1 works in
only one speed, take voltage
reading on the corresponding
in.link connector.
Turn Pump 1 to high speed
and take voltage reading
between:
Pump up to 20 Amp :
240 VAC: Pin 3 & Pin 1
120 VAC: Pin 3 & Pin 5
If voltage is as it should be,
replace Pump 1.
If not, replace Spa Pack.