Service manual

56
in.xe
"Ozonator doesn't work" step-by-step
If Ozonator is not working:
• Verify "Filter Cycle" indicator
appears steady on keypad.
• If the fi lter indicator is blink-
ing it indicates that the fi lter
cycle has been interrupted.
In that case, reset the breaker
by turning the power off and
on again to resume cycle.
• If not, start up a fi lter cycle
(see Programming fi lter
cycles section).
240 VAC at O3 connector:
Pin 2 & Pin 1
240 VAC
at O3 connector:
240 VAC at O3 connector: 240 VAC
Pin 2
Pin 1
• If you don't get a voltage
reading, replace the
accessory fuse.
• If voltage is as it should be,
replace ozonator.
• If not, replace Spa Pack.
120 VAC at O3 connector:
Pin 2 & Pin 5
120 VAC
at O3 connector:
120 VAC at O3 connector: 120 VAC
Pin 5
Pin 2
Accessory fuse
• If ozonator does not, work even
when fi lter cycle indicator is on,
take voltage reading on the cor-
responding in.link connector:
240 VAC: Pin 2 & Pin 1
120 VAC: Pin 2 & Pin 5
Your reading shoud be:
240 VAC for a 240 VAC
ozonator
120 VAC for a 120 VAC
ozonator