Service manual

56
in.xe
"Ozonator doesn't work" step-by-step
If Ozonator is not working:
Verify "Filter Cycle" indicator
appears steady on keypad.
If the lter indicator is blink-
ing it indicates that the lter
cycle has been interrupted.
In that case, reset the breaker
by turning the power off and
on again to resume cycle.
If not, start up a lter cycle
(see Programming fi lter
cycles section).

240 VAC at O3 connector:
Pin 2 & Pin 1
240 VAC
at O3 connector:
240 VAC at O3 connector: 240 VAC
Pin 2
Pin 1
If you don't get a voltage
reading, replace the
accessory fuse.
If voltage is as it should be,
replace ozonator.
If not, replace Spa Pack.
120 VAC at O3 connector:
Pin 2 & Pin 5
120 VAC
at O3 connector:
120 VAC at O3 connector: 120 VAC
Pin 5
Pin 2
Accessory fuse
If ozonator does not, work even
when lter cycle indicator is on,
take voltage reading on the cor-
responding in.link connector:
240 VAC: Pin 2 & Pin 1
120 VAC: Pin 2 & Pin 5
Your reading shoud be:
240 VAC for a 240 VAC
ozonator
120 VAC for a 120 VAC
ozonator