Service manual

74
in.xe
in.xe UL/CSA electrical specifications
Input rating : 120/240 VAC nominal (+ 5/- 10 %)
(2-phase required with neutral) 48 A Max,
60Hz nominal (+ 1. 5 / -1.0 Hz).
in.xe.ce electrical specifications
Input rating : 230/400 VAC nominal (+ 5/- 10 %)
single-phase system (10 to 40 A Max)
2-phase system (10 to 20 A Max)
50 Hz nominal (+ 1. 5 / -1.0 Hz)
Output ratings:
Output Voltage Current Typical Device
Out 1 120/240V 20 FLA/70 LRA (in-rush) Pump 1
Out 2 240 V
15 FLA/60 LRA (in-rush) Pump 2
Out 3 120/240V 6 FLA/60 LRA (in-rush) Circulation Pump
10 FLA (resistive load) (CP)/Blower
Important:
• All low voltage acccessories use + 5Vdc and/or + 12 Vdc.
• All low voltage acccessories combined: 150 mA max,
on + 12 Vdc.
• The maximum amperage for outputs 3 to 5 cannot
exceed 12 Amps.
heat.wav ratings:
Voltage: 120/240VAC
Current: 1120/240VAC
Current: 17A resistive (4 kW heater at 240V)
8.7 A resistive (2kW at 230v)
8.5 A resistive (1kW at 120v)
5.7 A resistive (1.3 kW at 230v)
Frequency: 50 / 60 Hz
heat.wav heater flow rate:
Minimum of 18 GPM is required
Output ratings:
Output Voltage Current Typical Device
Out 4 120/240V 6 FLA Ozone Generator
Out 5 120/240V 10 A Audio/Video device
L1 Light, 12VAC, 1 A
CO Communications port
Comm.connector (in.stik)
C1 Top side controller *
specifications