Service manual

75
in.xe
General specifications:
Environmental:
Operating temperature
NorthAmerican model in.xe:
–20˚C (-4˚F) to 60˚C (140˚F) for Pump 1 15 A
–20˚C (-4˚F) to 50˚C (122˚F) for Pump 1 20 A
European model in.xe-ce:
for single-phase system (1 x 32 A Max) or 2-phase (2 x 16 A)
–20˚C (-4˚F) to 60˚C (140˚F)
for single-phase system (1 x 40 A Max) or 2-phase (2 x 20 A)
–20˚C (-4˚F) to 50˚C (122˚F)
Storage temperature: -25°C (-13°F) to 85°C (185°F)
Humidity: up to 85% RH, non condensing
UL/CSA Standards:
UL 1563 Fifth Ed.
File: E182156
CSA No. 22.2 - 218.1-M89.
TUV Standards:
EN/IEC 60335 - 2 - 60: 2003/2002 - EN/IEC 60335 - 1: 2002/2001
(incl. Corr. & Am. up to 2004)
EN55014-1
EN55014-2
EN61000-3-2
EN61000-3-3
The in.xe is lab tested to IPx5 enclosure protection levels.
specifications
Mechanical:
Weight: 4.76 kg (10.5 lbs)
Dimensions (W x H x D):
Chassis: 441.5x298.5 x129 mm (17.38" x 11.75" x 5.1")
IPx5 level of waterproofing is conditional on 3 items:
• Both front covers (heater and input wiring) are closed and
screwed shut.
• A waterproof strain-relief/bushing is used for the cable entry into
the pack.
• Any unused in.link connections (HC, LC, or low voltage) is
plugged with the appropriate blank plug.