in.k450 compact full-function keypads for in.xe and in.
in.k450 table of contents Table of contents overview . ........................................................................................ 3 installation - drilling template...............................................................6 - with adhesive.................................................................... 7 connections - connecting in.k450 keypad to in.xe...............................8 - connecting in.k450 keypad to in.xm.............................9 functions for in.
in.
in.k450 overview in.k450 Compact full-function keypad for in.xm & in.xe spa systems Aeware’s new series of keypads features a large LCD display and slightly raised keys that let users control all spa system functions and programming directly from spa side. In.k450 comes with a customizable overlay in an easy to install waterproof plastic enclosure designed to maximize user experience.
overview in.
in.k450 overview Pumps icon The "Pump" indicator numbers light up and their icons become fast animated when pump or blower are in high speed, slower animated icon when pump or blower are in low speed. Time, temperature & message digits AM/PM (˚F/ ˚C) Filter Cycle icon The "Filter Cycle" icon lights up when filter cycle is on. Service icon Smart Winter Mode icon A problem has been detected. Do not enter the water! Spa service is required.
in.
in.k450 installation Installation in.k450 with adhesive The keypad should be installed directly onto the spa (or very close to it) so that it is easily accessible to the user. • Using the drilling template supplied with the unit, determine the mounting location and then stick the template on the location. 6 7/32" 158 mm Drill 2x 3/8” 2x 9 mm 2 5/16" 59 mm • Drill two 3/8” (9 mm) diameter holes at 6 7/32” (158 mm) from center to center, in the exact position according to the drilling template.
in.k450 connections Connecting in.k450 keypad to in.xe in.k450 keypad Keypad connector in.
in.k450 connections Connecting in.k450 keypad to in.xm in.k450 keypad Keypad connector in.
functions and user instructions in.k450 for in.xe spa systems in.k450 for in.
in.k450 for in.xe spa systems functions and user instructions On/Off key Standby Mode Economy Mode Pump 1 key Depending on the spa manufacturer, this key may have different functions: On/Off, Standby mode or quick enable of the Economy mode. Quick press and release the On/Off key to shut the system down (i.e. to set it to Standby mode) for 30 minutes. The display will toggle between the “SBY” message and water temperature.
functions and user instructions in.k450 for in.xe spa systems Pump 2 key Blower key Light key Up/Down keys Press Pump 2 key to turn Pump 2 on. Press a second time to turn pump off. Press Blower key to turn blower on. Press a second time to turn blower off. A built-in timer automatically turns pump off after a predetermined period of time, unless pump has been manually deactivated first.
in.k450 for in.xe spa systems functions and user instructions Program key Setting the time Setting filter cycle start time Setting filter cycle duration Use Program key to display time or enter Programming menu by pressing and holding key. In Programming mode, the following parameters can be set: time, filter cycle start time, filter cycle duration, filter cycle frequency, and temperature unit. Enter Programming mode by holding Prog. key pressed down for 3 sec.
functions and user instructions in.k450 for in.xe spa systems Filter cycle frequency Setting economy mode* Setting economy start time* Setting economy duration* Press Prog. key a fifth time. Press Prog. key a sixth time. Use Up key to enable the economy mode, the display will show EP 1 or use Down key to disable economy mode, the display will show EP 0. Press Prog. key an seventh time. The display will show ESxx, with “xx” representing the starting hour.
in.k450 for in.xe spa systems functions and user instructions Setting temperature unit Smart Winter Mode Water temperature regulation Cooldown Water temperature can be displayed in either Fahrenheit (˚F) or Celsius (˚C). Press Prog. key a ninth time. The display will show either ˚F or ˚C. Our Smart Winter Mode protects your system from the cold by turning pumps on several times a day to prevent water from freezing in pipes.
functions and user instructions in.k450 for in.xm spa systems in.k450 for in.
in.k450 for in.xm spa systems functions and user instructions On/Off key Depending on the spa manufacturer, this key may have different functions: On/Off, Standby mode or quick enable of the Economy mode. Standby Mode* : Use On/ Off key to pause all pumps.* Progress bar will display the remaining time before the system automatically exits Standby mode (user can also exit Standby mode at any time by pressing again on On/Off key).
functions and user instructions in.k450 for in.xm spa systems Pump 2 key Pump 3 / Blower key Light key Up/Down keys Press Pump 2 key to turn Pump 2 on at low speed. Press a second time to turn pump to high speed (with a dual-speed pump). A third time turns pump off. Press Pump 3/Blower key to turn Pump 3 /Blower on. Press a second time to turn pump or blower off. Press Light key to turn light on at high intensity. Subsequent presses change light intensity. A last press turns light off.
in.k450 for in.xm spa systems functions and user instructions Program key Setting the time Setting filter cycle start time Setting filter cycle duration Use Program key to display time or enter Programming menu by pressing and holding key. In Programming mode, the following parameters can be set: time, filter cycle start time, filter cycle duration, filter cycle frequency, and temperature unit. Enter Programming mode by holding Prog. key pressed down for 3 sec.
functions and user instructions in.k450 for in.xm spa systems Filter cycle frequency Setting economy mode* Setting economy start time* Setting economy end time* Press Prog. key a fifth time. This mode allows you to lower the temperature set point of the spa by 20 °F (11 °C) during a certain period of the day. Press Prog. key an seventh time. The display will show ESxx, with “xx” representing the starting hour. Press Prog. key a eighth time.
in.k450 for in.xm spa systems functions and user instructions Setting temperature unit Smart Winter Mode Water temperature regulation Cooldown Water temperature can be displayed in either Fahrenheit (˚F) or Celsius (˚C). Press Prog. key a ninth time. The display will show either ˚F or ˚C. Our Smart Winter Mode protects your system from the cold by turning pumps on several times a day to prevent water from freezing in pipes.
Troubleshooting section in.xm error codes in.k450 in.xe error codes Description The chosen input current rating is lower than the sum of current for all pumps. Call your electrician for tech support. Temperature inside the spa skirt is too high, causing the internal temperature in the Spa Pack to increase above normal limits. Open skirt and wait until error clears. If error persist, note the error message and contact dealer or service supplier for Tech Support.
in.k450 in.xm error codes Troubleshooting section in.xe error codes Description An internal hardware error has been detected Note the error message and contact dealer or service supplier for Tech Support. The system has shut the heater down because the temperature at the heater has reached 119°F (48°C). Do not enter the water! Remove the spa cover and allow the water to cool down, then shut power off and power your spa up again to reset the system.
Troubleshooting section in.xm error codes in.k450 Description A Pump problem has been detected Note the error message and contact dealer or service supplier for Tech Support. A Circ. Pump problem has been detected Note the error message and contact dealer or service supplier for Tech Support. A Blower problem has been detected Note the error message and contact dealer or service supplier for Tech Support.
in.k450 specifications Dimensions: General specifications: 2 7/8" (73 mm) 7 1/8" (181 mm) 2 3/16" (55 mm) 1 3/16" (30 mm) Environmentals: Storage temperature: Operating temperature: Humidity: 70˚C (158˚F) to –30˚C (-22˚F) 60˚C (140˚F) to –20˚C (-4˚F) up to 95% condensing Mechanical Specs: Weight: Dimensions (W x H x D): Standards: 0.52 kg (1.2 lbs) Front Panel: 181 mm x 73 mm x 55 mm (7 1/8" x 2 7/8" x 2 3/16") Soft gasket UL 1563 Fifth Ed. File: E182156 CSA No. 22.2 - 218.
Advanced electronics! Water resistance! Gecko Alliance 9919-100808-B Rev. 04/2015 450 des Canetons, Quebec City (QC) G2E 5W6 Canada, 1.800.78.GECKO www.geckoalliance.