User manual

58 Capricorn 2000EX Weather Station
___________________________________________________________________
Columbia Weather Systems, Inc.
28 SSE 157.5
32 S 180
36 SSW 202.5
40 SW 225
44 WSW 247.5
48 W 270
52 WNW 292.5
56 NW 315
60 NNW 337.5
The Short commands
WD: will display wind direction in 64 compass points (5.625 deg
resolution).
WS: will display wind speed in MPH
R1: will display the rain fall for the day in inches
RH: will display relative humidity percentage
P1: will display the barometric pressure in inches-Hg
T1: will display the temperature for the first temperature probe in degrees
F
T2: will display the temperature for the second temperature probe in
degrees F
T3: will display the temperature for the third temperature probe in
degrees F
T4: will display the temperature for the fourth temperature probe in
degrees F
LW: will display leaf wetness in volts. The range may vary per sensor.
Typically, 0.5 volts indicates saturated condition and 4.5 volts indicates
dry conditions.
X1: will display solar radiation (typically). 5.00 volts equals 2000 Wm-2.
X2: will display the value of the wind direction in 0 to 5 volts.
Datalog
The Capricorn 2000EX weather station has a built in circular datalogger.
The datalog holds records of sensor readings (Samples) and High/Low
information. Both types of records (Samples and High/Low) are recorded
at user defined intervals.
The datalog can hold up to 511 records. A Sample occupies on record
and High/Low information occupies four records.