User manual
Capricorn 2000EX Weather Station 61
___________________________________________________________________
Columbia Weather Systems, Inc.
undefined sensors (X1 and X2). The low value of wind speed is the high
4 second sustained wind average.
Setting temperature offsets
Temperature offsets are used to calibrate the temperature probes.
n TCAL#: This command is used to enter an offset for a temperature
probe. Where n is the offset in 1/100 of a degree F and # is the
temperature probe number.
Example: 231 TCAL2 adds 2.31 degree F to the temperature reading
from temperature probe two and -231 TCAL2 subtracts 2.31 degrees F
from the reading.
Please refer to the Temperature Calibration section for more information.
Setting barometric pressure altitude and
offset
n ALT: This command sets the altitude of the weather station, where n is
the altitude in feet.
Example: 225 ALT sets the altitude to 225 feet above sea level.
n BAR-OFFSET: This command is used to enter an offset to the
barometric pressure reading, where n is the offset in 1/100 of In.Hg.
Example: 34 BAR-OFFSET adds 0.34 in.Hg to the barometric pressure
reading and -34 BAR-OFFSET subtract 0.34 in.Hg from the reading.
Please refer to Barometric Pressure Calibration for more information.
Display current settings
PARAMETERS: This command displays the current weather station
settings and the number of records in the datalog.
Example:
Date & Time 02/11/2007,17:31
Measurement interval 1 minute
Hi/Lo interval 1 hours
Records in memory 262
Pressure offset 38
Altitude 225
Temperature 1 offset 255
Temperature 2 offset -25
Temperature 3 offset 55
Temperature 4 offset 155 ok