User manual
62 Capricorn 2000EX Weather Station
___________________________________________________________________
Columbia Weather Systems, Inc.
Continuous display of direction
NORTH: This command continuously displays the wind direction. This
command is used for locating the north direction on the wind sensor. An
<Esc> followed by a carriage return terminates this command.
Continuous display of weather
information
1 XFER: This command continuously displays a Sample record every 15
seconds and wind speed and direction every one second. The wind
speed and direction record starts with the letter W followed by three
digits for wind speed in MPH followed by two digits for wind direction.
Example:
W00124
S,02/11/07,17:44,24WD,001WS,00.08R,085RH,29.82P1,+048.56T1,+070.85T2,+067.24T3,+065.0
8T4,01.74LW,0.00X1,0.00X2,6014
W00224
W00224
W00124
W00124
W00124
W00120okok
An <Esc> followed by a carriage return terminates this command.
XSET: This command defines the frequency the Sample record is
displayed in the XFER output. The default frequency of the Sample
record in the XFER output is 15 seconds. This frequency can be
changed using the XSET command. For example, 60 XSET will cause
the Sample record to be issued every 60 seconds. XSET will change the
frequency of the XFER output on both serial ports.
CONT: This command will continuously output the Sample record at a
specified interval. For example, 5 CONT will output a Sample record
every 5 seconds. The time interval is limited to a range of 1 to 16
seconds.
S,05/01/99,09:44,40WD,000WS,00.00R,022RH,29.10P1,+070.70T1,+255.00T2,04.80LW,5.00X1,0
.10X2,4923
S,05/01/99,09:44,40WD,000WS,00.00R,023RH,29.09P1,+070.70T1,+255.00T2,04.80LW,5.00X1,0
.10X2,4932