Datasheet
CODICE – CODE: 
CE0467 
CARATTERISTICHE ELETTRICHE E 
MECCANICHE 
Electrical & Mechanical Specifications 
FOGLIO - SHEET: 
3 of 10 
DATA – DATE: 
12-03-2010 
All parts included in this documentation are property of 
COMATEC snc. All rights reserved. This document and 
its information (or part of its) can't be reproduced or used 
without an explicit written permission. 
All technical specifications are 
subjected to change without notice. 
EDIZIONE – ISSUE: 
1
st
 Edition 
CARATTERISTICHE D'INGRESSO Input Requirements 
Tamb=25°C, f=50Hz se non specificato altrimenti  Tamb=25°C, f=50Hz unless otherwise specified 
N°  PARAMETRO 
Parameter 
CONDIZIONI 
Conditions 
MIN  TYP  MAX  UNITÀ 
Unit 
1 Input Voltage 
Range 
  100-240 (+/- 10%)  Vac 
2 Input Frequency 
Range 
 50  60 Hz 
3  Input Current  Full load; Vin=100Vac; Vout=24V 
No load; Vin=230Vac; Vout=28V 
Full load; Vin=230Vac; Vout=24V 
 0.95 
20 
0.51 
 Arms 
mArms 
Arms 
4  Inrush Current  Full load; Vin=265Vac; deg=0° 
Full load; Vin=265Vac; deg=90° 
Full load; Vin=265Vac; deg=270° 
13 (6.0 ms) 
24 (2.5 ms) 
22 (2.5 ms) 
Apk 
Apk 
Apk 
5  Protection in the 
mains supply line 
Standard EN60898 
Standard EN60947-2 
3A Char. C 
10A Char. Z 
6  Power Factor  Vin=100-240Vac; full load  0.46    0.60   
7  Efficiency  Vin=100Vac; full load 
Vin=230Vac; full load 
 86 
89 
 % 
% 
8  No Load Input  Vin=100Vac; No load; Vout=28V 
Vin=230Vac; No load; Vout=28V 
 1.4 
0.9 
 W 
W 
Note1: The range of source voltage for which the power supply is guaranteed to meet its specifications. 
Note2: The range of source frequency for which the power supply is guaranteed to meet its specifications.
Note3: The maximum value of the steady state AC input current, measured for any combination of rated AC 
voltage and environment and for any combination of rated continuous output loading (up to a maximum of 
Watts). 
Note4: The high surge of input current that occurs upon initial turn-on, after an OFF period of at least 
10 seconds. 
Note5: The connection to the mains line should be made using an all-pole mains switch (with a contact 
separation of at least 3mm in each pole) with the shown characteristics. 
Note6: The ratio of actual power used in a circuit to apparent power, for any combination of AC input 
voltage. Power factor is the measure of the fraction of current in phase with the voltage and 
contributing to average power. 
Note7: The ratio of output power to input power, measured at full load and for any combination of the 
rated AC input voltage. 
Note8
: The input power, measured without load. 