Datasheet
CODICE – CODE: 
CE0467 
CARATTERISTICHE ELETTRICHE E 
MECCANICHE 
Electrical & Mechanical Specifications 
FOGLIO - SHEET: 
4 of 10 
DATA – DATE: 
12-03-2010 
All parts included in this documentation are property of 
COMATEC snc. All rights reserved. This document and 
its information (or part of its) can't be reproduced or used 
without an explicit written permission. 
All technical specifications are 
subjected to change without notice. 
EDIZIONE – ISSUE: 
1
st
 Edition 
CARATTERISTICHE D'USCITA Output Requirements 
Tamb=25°C, f=50Hz se non specificato altrimenti  Tamb=25°C, f=50Hz unless otherwise specified 
N°  PARAMETRO 
Parameter 
CONDIZIONI 
Conditions 
MIN  TYP  MAX  UNIT
À 
Unit
1  Rated Output Voltage  Iout=1
A
(half load) 
Adj.by front panel trimmer 
24 to 28 
24 (+/-3%) 
Vdc 
2  Output Current Range    0    2  Adc 
3  Rated Output Power        48  W 
4  Derating        
5  Line Regulation  Half load    +/-0.01    % 
6  Load Regulation  Vin=230Vac   +/-0.25  % 
7  Output Ripple 
- line component 
- switching component 
Full load 
Vin=100-240Vac 
Vin=100-240Vac 
< 10 
20 
mVpp 
mVpp 
8  PARD  Vin=100-240Vac; full load    20    mVpp
9  Iob      
10 Set-up Time      
11 Hold-up Time      
12 Repetitive Dynamic 
Load 
Vin=100Vac 
Vin=240Vac 
 270 
320 
 mVpp
mVpp
Note1: The DC voltage measured at the output terminal blocks, for any combination of rated AC voltage, 
environment and AC input frequency. 
Note2: Output current limits within that the power supply is in regulation (see point 1). 
Note3: The maximum steady-state power which the equipment is guaranteed to be able to deliver, while 
continuing to meet its other specifications. 
Note4: Reduction in output power (or current) as a function of case temperature above the maximum full-
load rated case temperature. 
Note5: Amount of change in the DC output voltage (expressed in percentage of rated output voltage) as the 
input voltage is varied over its specified range. 
Note6: Amount of change in the DC output voltage (expressed in percentage of rated output voltage) as the 
load is varied over its specified range. 
Note7: Unwanted portion of output voltage harmonically related in frequency to the input line and to any 
internally generated switching frequency. The measuring are made directly at the terminal of the power 
supply. They take place at rated input voltage and rated output current, with an oscilloscope that has 
bandwidth limitation of 20MHz (if not, the common-mode disturbances will distort the results and 
reproducibility is not given). In accordance with EN61204, for the low frequency measurement, the normal 
single-ended method is adequate. For switching noise a special differential test arrangement is being 
used. 
Note8: Measures all disturbances (superimposed to output voltage), including the spikes, high frequency 
voltage peaks caused, among others, by steep switching slopes. It takes place at nominal input voltage 
and nominal output current, with an oscilloscope that has bandwidth limitation of 20MHz for 
reproducibility reasons. In accordance with EN61204, for PARD a special differential test arrangement is 
being used. 
Note9
: Output current (measured at nominal input voltage) at the boundary between continuous and 
discontinuous mode operation. 
Note10
: Time duration from power supply turn-on until its output voltage goes up into a regulated limit 
(Vout = Vnom – 3%). 
Note11: Time duration from power supply turn-off until its output voltage goes down into an unregulated 
limit (Vout = Vnom – 3%). 
Note12: Output voltage ripple (expressed in mVpp) measured when the output is dynamically loaded as 
follows: Imin to Imax to Imin (slew rate = 3.2mV/us, duration = 100ms). 