Datasheet
CODICE – CODE: 
CE0467 
CARATTERISTICHE ELETTRICHE E 
MECCANICHE 
Electrical & Mechanical Specifications 
FOGLIO - SHEET: 
7 of 10 
DATA – DATE: 
12-03-2010 
All parts included in this documentation are property of 
COMATEC snc. All rights reserved. This document and 
its information (or part of its) can't be reproduced or used 
without an explicit written permission. 
All technical specifications are 
subjected to change without notice. 
EDIZIONE – ISSUE: 
1
st
 Edition 
MECCANISMI DI PROTEZIONE Protection Mechanisms 
Tamb=25°C, f=50Hz se non specificato altrimenti  Tamb=25°C, f=50Hz unless otherwise specified 
N°  PARAMETRO 
Parameter 
CONDIZIONI 
Conditions 
MIN  TYP  MAX  UNITÀ 
Unit 
1 Input Under 
Voltage 
Full load    65    Vac 
2  Input Over-Current  By Fuse    T 1.6    Aac 
3 Input Inrush 
Current 
See pag.3         
4 Out Current 
Limiting 
Vin=100Vac 
Vin=230Vac 
Vin=240Vac 
 2.7 
3.1 
3.1 
 Adc 
Adc 
Adc 
5  Out Over-current    Lean-forward mode   
6 Out Short-circuit  Vin=100-240Vac    3.5    Adc 
7  OV and open-loop    Latch mode   
8  Out Uder-voltage    NOT PRESENT   
9 High Temperature           
Note1: The device shall shutdown without latch-off if the input voltage goes down the specified limit. 
Note2: The device has an internal over-current protection. A delayed-blow, high breaking capacity fuse 
(not accessible) is placed in the line side of the input circuit. 
Note3: The device has an internal inrush current protection. A NTC resistor (not accessible) is placed in 
the line side of the input circuit. 
Note4: Maximum steady-state output current obtainable from the regulated output. 
Note5: The device shall not be damaged when input power is applied with an output over-current. During 
this condition the device produces a “LEAN FORWARD MODE” working. 
Note6: The device shall not be damaged when input power is applied with an output short circuit (less 
than 0.1 ohm). During this condition the device produces an “LEAN FORWARD MODE” working. 
Note7: The device shall shutdown with latch-off the output. It is necessary to remove the mains supply 
and restart the device (the output voltage never exceeds 35V). 
Note8: When the output voltage goes down specified value, the device shall shutdown without latch-off the 
output. 
Note9: When the junction temperature reaches specified value the controller IC shall shutdown and 
protects other components from failure. The temperature protection is not latching; after an over-
temperature shutdown, the controller will restart as temperature drops. 
LEAN FORWARD MODE
 = the equipment permits the current to be increased 
by a factor 1.7 of the maximum rated value, and slowly reduces the 
output voltage (up to 0 volts, during short-circuit). This increased 
current is permanently available, so that the device neither switches-
off nor hiccups as a result of overload or short-circuiting. 