USER MANUAL FOR COMFLEX 6100 1W
ENU STATUS : 1-0-0
Copyright - refer to title page
Page 52
Figure 66: Dev Info & Date/Time
Dev Info mainly used to record device location and Date/Time provid a time reference. Mouse click the
Config Value of Date/Time to auto receive the computer time.
NOTE: Make sure all the ANT ports of RUs are connected with dummy load or antenna system
before proceeding to step 4.
Step 4: Click
to enter to MU Calibratiion page after finishing Parems Setting.
Select a frequency band that need to calibrate from the table in the middle of the page.
Read Tip1 on the left side and click of Tip 1
Input signal to a RF port of RFU which you want to calibrate.
Read Tip2 on the left side and enther the input power in the box (Suggested input power 10-
30dBm). Input power has to be >10dBm for successful calibration.
Click .
Tip of MU calibration finish will show up on the left of the page, and calibration results will
show in the table.
NOTE: Each RFU needs to be calibrated; click “More” at last step of process to calibrate next
RFU.