See the table below for configuration details of each parameter.
Item
Description
Site ID
Site ID is the unique equipment identification. It is a hexadecimal string of eight
characters in the range of [00000000~FFFFFFFF]. e.g. 00000000
Site Sub ID
Site Sub ID is used for Master-Slave System. It is the unique identification of each
Master/ Slave Unit and is a hexadecimal string of two characters in the range of
[00~FF].
For the system located with single equipment, the Site Sub ID should be FF.
For Master-Slave system, the Site Sub ID for Master Unit is 00, and the Site Sub
ID for each Slave Unit is represented in the range of [01~FE] in ascending order.
e.g. Master Site ID: 00, Slave Site ID: 01
7.1.8 BS-8132&BS-1933 BSU CONNECTORS
DT
Front Panel
MT
RUN ALM
PWR
RS232
AC 100V-240V
50Hz/60Hz
Rear Panel
Figure 64: BSU Connectors
Identifier
Functional Description
DT
SMA connector, connects with BTS
MT
SMA connector, BS-8132_MT connects with RA-5700D_850MHz connector
while BS-1933_MT connects with RA-5700D_1900MHz connector
RUN
Operation indicator
ALM
Alarm indicator
PWR
Power supply indicator
RS232
DB9 connector, connects to PC via engineering OMT.
AC 100-240V
50Hz~50Hz
Power supply