User's Manual

ENU STATUS : 1-0-0
Copyright - refer to title page
Page 28
INSTALLATION GUIDE FOR RX-7W22, II2
Table 4: Commissioning Task Explanation
Commissioning Tasks
Observation
1. Isolation detection
Detect isolation of service antenna and donor antenna.
2. Set control channel
frequencies
Enter the center frequency of the main control channel, the
commissioning guide will provide recommended DL/UL gain
settings based on main control channel input power and the total
channel numbers.
Users can skip this step and directly finish the commissioning guide
even if the frequency information or the total channel numbers are
unknown. Users can set the DL/UL gain manually any time after the
isolation detection has been completed and passed.
3. Set Channel No.
Enter the total channel numbers
4. Recommended DL and UL
gain parameters
The commissioning guide will provide recommended DL/UL gain
settings.
Users will still need to set all the gains manually in the “Device”
pages, and the frequencies for all the independent channels in the
same “Device” pages after the commissioning process is finished.
End of Section