ENU:1-0-0 Copyright Comba Telecom Ltd., March 2009. All rights reserved Page2-17
2.3 POWER SUPPLY REQUIREMENT
The power cable selection should rely on the distance between rectifier and Backplane. At the
power terminal of Backplane for MCPA and Cooling Fans, a 27+/-1Vdc is needed.
CAUTION
z The AC or DC power source must be connected to dedicated lightning
arrestor to avoid damage to TBS system in case of lightning.
z All modules of TBS system should be well grounded.
2.3.1 UNPACKING AND INSPECTION
TBS system was factory tested, inspected, packed, and delivered to the carrier with utmost
care. When the equipment is delivered to installation site, go through the following unpacking
and inspection process.
1: Carefully unpack and check each package/container against the packing list. For any
shortage, double confirm with carrier. Do not remove items from packing materials until
installation.
2: Visually inspect the enclosure, connectors, and cables for damage caused by improper
shipment. Try to check whether there is evidence for water leakage, bent or wrapped chassis,
loose screws or nuts, or extraneous packing material in the connectors or fans. Inspect male
connectors on modules and harnesses for bent connector pins.
Note: 1. If the equipment is damaged or something is missing, do not accept shipment
from carrier until the carrier's agent endorses a statement of the irregularity on the
face of the carrier's receipt. Without documentary evidence, a claim cannot be
processed.
2. After confirm with carrier and delivery person, if the equipment needs to be
returned to factory, contact with Comba local office (see Appendix B) to get a return
authorization and go through RMA process (Refer to Appendix C)