MCPA TBS SYSTEM USER MANUAL
ENU:1-0-0 Copyright Comba Telecom Ltd., March 2009. All rights reserved Page3-21
Red MCPA is abnormal and there should be some Major alarm
3.1.2 CONTROL MODULE CONTROL AND INDICATORS
Except the status of MCPA can be visually monitored and controlled, the front panel of System
Controller also have LED indicators and interfaces for system diagnosis and commissioning.
The front panel is shown as following. The function and purpose are explained in table 3-x.
Figure 2: Indicators and Interface on Front Panel of System Controller
Table 4: Functions of Indicators and interfaces of System Controller
Indicators/Interfaces Status
Functions
Green +27DC power to the system is normal
POWER LED
Black (OFF) +27Vdc power supply is unavailable.
Green
All 6 cooling fans are in normal running.
FAN LED
Orange Minor Alarm: Cooling Fan is abnormal.
Green The system is in normal operation, no alarms.
Orange
The system is abnormal and there should be some minor
alarm.
Status LED
Red
The system is abnormal and there should be some major
alarm.
Ethernet Port
Used for local PC connection for commissioning and monitoring. This port is
also reversed to connect to BTS controller for TBS system remote
commissioning and monitoring.
USB Port Factory use
LED Indicators
PC Interface