Multi Internal Remote Control Unit (MIRCU) User Manual Document Version 1.
MIRCU User Manual Contents 1 2 3 Foreword ................................................................................................ 2 Safety Precaution .................................................................................. 3 Overview ................................................................................................ 3 3.1 Main Purpose & Scope of Application ............................................................ 3 3.2 Model Description..............................
MIRCU User Manual 1 Foreword This user manual describes the basic use of electrical tilt antenna connected to the Multi Internal Remote Control unit (MIRCU). Due to different equipment and software upgrade, some description in this manual may differ from the actual use. Information contained in this document is subjected to change without prior notice. © Comba Telecom Ltd.
MIRCU User Manual 2 Safety Precaution Install safety sign onsite to let public know that area is dangerous for public; operating personnel must use Protection Equipment during work. Pay attention for any high Voltage cable around during installation, be careful and avoid electrical shock. Make sure Antenna installed in protection angle of the tower Lightning rod. Grounding Cable must be installed, make sure the grounding resistance lesser than 5Ω. 3 Overview 3.
MIRCU User Manual Figure 1 IRCU Outline Size and weight are shown in Table 1 below: Model MIRCU-S24 Dimensions (L × W × H)/mm 141x125x41 Weight/kg (Approximate) 0.5 Package Size (L × W × H)/mm 160×178×87 Table 1 IRCU Dimensions and Weight 4 MIRCU Specification For MIRCU specification please refer to MIRCU Datasheet. MIRCU tilting angle with adjustment accuracy of ± 0.1 °. 5 RET System and Working Principle 5.
MIRCU User Manual shifter in an antenna, and thus able to control antenna electrical tilt angle. While maintaining real time communication between MIRCU and PCU (Portable Control Unit), PCU send control command to MIRCU; MIRCU will return the control result to PCU, and PCU act as Human-Machines interface. 5.3 2 Primaries Working Principle The MIRCU-S24 module has 2 pairs of AISG ports and supports AISG3.0 protocol, and can be controlled by 2 primaries (Base Stations) which meet AISG2.0 or AISG3.
MIRCU User Manual RET PROT1 PORT2 CB01CB20C1234567-Y1 Read & Write No Access CB02CB20C1234567-Y2 Read & Write No Access CB03CB20C1234567-Y3 Read & Write No Access CB04CB20C1234567-Y4 Read & Write No Access CB05CB20C1234567-R1 No Access Read & Write CB06CB20C1234567-R2 No Access Read & Write CB07CB20C1234567-R3 No Access Read & Write CB08CB20C1234567-R4 No Access Read & Write When the AISG2.
MIRCU User Manual 2nd Primary Scan Calibrat ion Set Tilt L2 Restora tion L7 Restora tion Update Config file Update Firmwar e Informa tion Set Device Data Self-test Scan √ √ √ √ √ √ √ √ √ √ Calibration √ X X √ √ X X √ √ √ Set Tilt √ X X √ √ X X √ √ √ L2 Restoration √ √ √ √ √ √ √ √ √ √ L7 Restoration √ √ √ √ √ √ √ √ √ √ Update Config file X X X X X X X X X X Update Firmware X X X X X X X X X X Information √ √ √ √ √ √
MIRCU User Manual 2nd Primary Action Scan Calibration Set Tilt L2 /L7 Restoration Update Configuration File Update Firmware Get Information Set Device Data Self-test If MIRCU Support Support Support Support Support Support Support Support Support Support Impact on 1st Primary No Impact No Impact No Impact No Impact Broken Link Broken Link No Impact No Impact No Impact b) Calibration MIRCU-S24 does NOT support 2 primaries to perform calibration simultaneously.
MIRCU User Manual 2nd Primary Action Scan Calibration Set Tilt L2 /L7 Restoration Update Configuration File Update Firmware Get Information Set Device Data Self-test If MIRCU Support Support Reply “Busy” Reply “Busy” Support Reply “Busy” Reply “Busy” Support Support Support Impact on 1st Primary No Impact No Impact No Impact No Impact No Impact No Impact No Impact No Impact No Impact d) L2 /L7 Restoration MIRCU-S24 supports 2 primaries to restore L2 or L7 simultaneously.
MIRCU User Manual h) Set Device Data MIRCU-S24 supports 2 primaries to set device data simultaneously. When 1st primary is setting device data, the 2nd primary is able to scan, calibrate, set tilt, restore L2/L7, update configuration file, update firmware, get MIRCU information, set device data and self-test. **Note: The data that can be changed include Installation date, Installer's ID, Base station ID, Sector ID, Antenna bearing (degrees), Installed mechanical tilt (degrees) and Antenna serial number.
MIRCU User Manual 2nd Primary Action Scan Calibration Set Tilt L2 /L7 Restoration Update Configuration File Update Firmware Get Information Set Device Data Self-test 5.3.2 If MIRCU Support Support Support Support Support Support Support Support Support Support Impact on 1st Primary No Impact No Impact No Impact No Impact Broken Link Broken Link No Impact No Impact No Impact Operation in AISG3.
MIRCU User Manual Note 2) 1 primary can operate the command successfully, but the command sent by another primary failed to achieve. √:Note 1) MIRCU-S24 can operate the commands from 2 respective primaries simultaneously, and comply with AISG standard. Note 2) ‘When “RESETALD” is run on 2nd primary when 1st primary is performing an action, all the action on the 1st primary will be suspended. a) Scan MIRCU-S24 supports 2 primaries to scan MIRCU simultaneously.
MIRCU User Manual MIRCU-S24 does NOT support 2 primaries to set tilt simultaneously. When 1st primary is setting tilt, the 2nd primary is able to scan, reset port, reset ALD but NOT able to calibrate, set tilt, upload/download file, configure MALD and ping.
MIRCU User Manual The file download command starts with ‘DownloadStart’ and ends with ‘DownloadEnd’. The file is carried and downloaded by using ‘DownloadFile’ command. The supported file types are FirmwareFile and ConfigureFile. The module does not support multiports file download operation simultaneously, which mean when 1st primary is performing download, the 2nd primary ports will be close and no operation can be performed.
MIRCU User Manual 2nd Primary Action If MIRCU Support Scan Support Calibration Return “IncorrectState” Set Tilt Return “IncorrectState” ResetPort Support ResetALD Support Upload File Return “IncorrectState” Download File Return “IncorrectState” MALD Configure Return “IncorrectState” PING Return “IncorrectState” Impact on 1st Primary No Impact No Impact No Impact No Impact Broken Link No Impact No Impact No Impact No Impact 6 MIRCU Installation and Connection 6.
MIRCU User Manual 6.1.3 Installation Tools 32mm open-end Torque wrench x 1. 6.2 MIRCU-S24 Installation 6.2.1 MIRCU-S24 Installation Steps and Methods a) As shown in Figure 2, "AISG OUT" logo on Antenna cover need to be aligned with MIRCU “IN” and “OUT”, then insert MIRCU into antenna mounting slot. Figure 2 MIRCU Alignment b) As shown in Figure 3, tighten screws on MIRCU using a slotted type screwdriver. © Comba Telecom Ltd.
MIRCU User Manual Figure 3 MIRCU Installation c) As shown in Figure 4, connect the control cable to the AISG Connector locate at the lower part of the MIRCU and tighten the connector. Figure 4 AISG Control Cable to PCU d) If there is more than one MIRCU need to be connect, daisy-chained cascade method can be used as show in Figure 5. © Comba Telecom Ltd.
MIRCU User Manual Antenna AISG IN Antenna AISG IN AISG OUT Antenna AISG OUT AISG IN AISG OUT Cable Daisy Chain Connection Daisy Chain Connection PCU 200 H- UCP Figure 5 Multiple MIRCU Daisy-Chain Cascade Schematic Diagram **Note: The control cables and MIRCU connectors at both ends were Male and Female connector.
MIRCU User Manual (a) (b) Antenna Antenna (c) Antenna SBT AISG TMA SBT SBT PCU BTS 200H- UCP Figure 6 MIRCU, PCU and Antenna System Connection Diagram 6.3 Mapping of MIRCU to Phase Shifter Comba existing MIRCU can satisfy 1 to 8 RET phase shifter control, and will be upgraded to support up to 20 phase shifter control in near future through firmware upgrade, expected to be done by Q2 2021. All control and driver chip are integrated into a single MIRCU module.
MIRCU User Manual Internal spline to connect phase shifter Internal switch model to connect phase shifter Figure 7 MIRCU-S24 Plug-and-play Installation Internal control model to connect PING control board Figure 8 MIRCU-S24 Ping Selection board Plug-and-play Installation Each Driver Unit/Motor comes with their own serial number. For Figure 9 below, 8 set of serial numbers will be displayed on PCU when connected. © Comba Telecom Ltd.
MIRCU User Manual Figure 9 Mapping of MIRCU-S24 to Phase Shifter 6.4 MIRCU Control Cable, Lightning Protection and Grounding cables 6.4.
MIRCU User Manual Figure 10 c) Control cables metal sheath attach to grounding kit as shown in Figure 11. Control Cable Grounding Kit Grounding Cable Connect to grounding bar Figure 11 6.4.2 Grounding Kit Installation Procedure a) Prepare ground kit, as shown in Figure 12 1a. b) Clean the plastic sheath of the control cables, cutting plastic sheath with a suitable stripper tool, expose metal braid sheath of control cable, with length about 22mm, as shown in the Figure 12 1b.
MIRCU User Manual d) Tighten the screws of the grounding kit, as show in Figure 14. e) Connect and tighten grounding cable on the grounding bar which locate at bottom of the tower. **Note: The control cables should be in upright position while clamping with grounding kit. Figure 12 Figure 13 Figure 14 7 Transportation and Storage 7.1 Transportation Equipment can be carriage by car, train, ship, airplane or other transportation vehicles.
MIRCU User Manual 8 Caution and Note 8.1 Caution Caution: The user is cautioned that changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 8.