Specifications

4
4 • VonDuprinDoorcontrolandsecurityhardware
4200 Series electric strikes for cylindrical locks
4200 Series electric strikes for cylindrical locks
Overview
The 4200 Series electric strikes are easy to order, configure in the
field and install. This makes it a great choice for commercial
applications where trac control is the primary function.
Compatible with a wide range of cylindrical devices, the 4200
series makes electrifying an opening simple. It is designed and
tested to work will all Schlage and Falcon cylindrical locks as
well those of many other manufacturers’.
With a variety of field configurable options, the 4200 series is
able to address a broad range of needs. The power failure mode
(fail safe or fail secure) can be changed in the field without
disassembling the strike. The 4200 series also features a 12/24
dual-voltage solenoid for field wiring of either input voltage.
Additional factory orderable options provide even greater
flexibility. The 4200 series can be ordered with or without
latchbolt monitor. Square face plate is offered standard to
accommodate hollow metal frames, and rounded corner
faceplates are available as an option for aluminum frames.
An entry buzzer and rectifier kits are also available options.
The 4200 was developed with Von Duprin’s high standards and
engineering expertise. Its heavy duty stainless steel construction
is designed to withstand abuse.
Features
§ Field configurable 12/24 voltage utilizing dual-voltage internal
solenoid
§ Field configurable power failure mode (fail-safe/fail-secure)
§ Non-handed, internal solenoid design
§ Heavy duty stainless steel faceplate
§ Latchbolt monitoring standard on 4212 only
§ Optional entry buzzer and rectifier kits available for AC to DC
operation
§ 1 year electrical product warranty
Lockset compatibility
The 4200 series is compatible with all Schlage and Falcon
cylindrical locks as well as cylindrical and deadlatch locks of
many other manufacturers.
§ The 4211 is compatible with locksets with
5
8" (15 mm) throw
latchbolts, or up to
3
4" (19mm) throw latchbolts with a
1
8"
door gap.
§ The 4212 is compatible with locksets with
1
2" (12.7mm) throw
latchbolts, or up to
5
8" (15 mm) throw latchbolts with a
1
8"
door gap.
Technical specifications
Strike 12 VDC 12 VDC
Current (amps) 0.20 A 0.10 A
Latchbolt monitor 30 VDC
Current (amps) 0.20 A
The 4200 series requires a DC regulated power supply, and the Schlage PS900 series
power supplies are recommended.
Model specifications
Model number 4211 4212
Latchbolt throw
3
/
4
"
5
/
8
"
Latchbolt monitor switch ---
Face plate length 4
7
/
8
" 4
7
/
8
"
Backbox depth 1
3
/
8
" 1
3
/
8
"
Lockset Cylindrical
Deadlatch
Mortise --- ---
Rim exit devices --- ---
Number
of doors
Single
Pair --- ---
Door and
frame type
Hollow metal
Aluminum
Wood --- ---
Options EB (entry buzzer -
fail-secure only)
SO12 & SO24 rectifier
kit for AC to DC
operation
Round corner faceplate