Warnings
Install the equipment by carefully following the instructions given by the manufacturer and in compliance with the standards in force.
All the equipment must only be used for the purpose it was designed for. Comelit Group S.p.A. declines any responsibility for improper use of the apparatus, for any alterations made
by others for any reason or for the use of non-original accessories or materials.
All the products comply with the requirements of Directive 2006/95/EC (which replaced Directive 73/23/EEC and subsequent amendments) as certified by the CE mark they carry.
Do not route the riser wires in proximity to power supply cables (230/400V).
Installation, mounting and assistance procedures for electrical devices must only be performed by specialised electricians.
Cut off the power supply before carrying out any maintenance work.
Description of Art.1456B
Article 1456B is a multi-apartment gateway that:
can serve up to 200 apartments, with a maximum of 15 slave devices per apartment;
can answer calls from a external unit via a virtual door entry monitor App for smart phone/tablet or using a normal GSM or landline telephone;
incorporates the SIP protocol to enable telephone calls via SIP server or via virtual lines purchased from a SIP services provider;
allows up to 4 simultaneous audio/video calls;
can be configured remotely from a web page.
1. Ethernet port for ViP system riser input (default addressing: Autoip).
2. Dip switches for the procedures "Reboot with predetermined network settings" on page 19 and "Restoring factory settings" on page 20.
3. Power supply input via Art. 1441, Art. 1441B.
4. CV1 and CV2 for setting port A2.
5. CV3 and CV4 for setting port A3.
6. A4 non POE Ethernet port for PC or router connection (default: Static IP address 192.168.1.200, netmask 255.255.255.0).
7. A3 non POE settable Ethernet port POE (default: Static IP address 192.168.1.200, netmask 255.255.255.0). Set the port as POE if you want
to connect devices that require a power supply (door entry monitors, for example).
8. A2 non POE settable Ethernet port POE (default: Static IP address 192.168.1.200, netmask 255.255.255.0). Set the port as POE if you want
to connect devices that require a power supply (door entry monitors, for example).
9. A1 Ethernet port POE (default: Static IP address 192.168.1.200, netmask 255.255.255.0).
* Only connect to the router
or PC using the red Comelit
cable 2E7T000500
SETTABLE POE
A2 A3
SETTABLE
CV1 CV2 CV3 CV4
CV1 CV2 CV3 CV4
POE
DO NOT USE
STANDARD
ETHERNET*
CV1 CV2 CV3 CV4
CV1 CV2 CV3 CV4
POE
DO NOT USE
STANDARD
ETHERNET*
DEFAULT
CV1 CV2 CV3 CV4
CV1 CV2 CV3 CV4
NON POE
STANDARD
ETHERNET
CV1 CV2 CV3 CV4
CV1 CV2 CV3 CV4
NON POE
STANDARD
ETHERNET
< BACK