Manual

20
OFF
ON
OFF
ON
OFF
ON
a
c
b
Restoring factory settings
With the dip switches in the default positions (OFF).
» The device will reset all parameters to the factory settings and restart in the normal way.
This procedure allows you to restore all the factory parameter settings and to delete all the device configurations.
1. Switch off the power supply to the device.
2. Set all the dip switches to ON.
3. Power on the device.
4. Wait 20 - 40 seconds, until the LEDs start flashing rapidly and alternately (0.1 sec red / 0.1 sec green).
5. Return all the dip switches to OFF.
» The red LED will flash for 5 seconds.
WARNING: the full reset procedure also deletes and the licenses installed on the device
You can restore the licenses (max. 2 times) using the procedure described in the following paragraph.
Restoring licenses
1. From ViP Manager, look for the device 1456B as described in the ViP Manager addressing procedure (page 4).
2. Select the device 1456B [a].
3. Press "Add license" from the main menu [b].
4. Press "Load from server" to restore previously activated licenses [c].
The following procedure allows you to restore licenses lost during the full reset procedure:
Licenses can be restored a maximum of two times only. For additional license restore operations, contact Comelit technical assistance.
< BACK