Self-testing
On power-up, the device carries out a diagnostic test of
the connections to check the correct communication and
conguration of the porter module (Art. 1622, 1622VC,
1621, 1621VC, 1682, 1682HVC, 4680C, 4681, 4682HC).
The message PLEASE WAIT indicates self-testing in pro-
gress. On completion of self-testing, press the key to
put the module in standby.
The word OK should appear next to the menu items with
the name SIMPLEBUS, SIMPLEBUS TOP or ViP under-
neath, depending on the conguration of the porter module
and the directory module.
If the following message appears:
- FAILED check correct serial connection between direc-
tory module and porter module Art. 1622, 1622VC, 1621,
1621VC, 1682, 1682HVC, 4680C, 4681, 4682HC.
- ERROR check congruency of conguration (SIMPLE-
BUS, SIMPLEBUS TOP or VIP) of directory module and
porter module see “5. Setting call management” page 13).
INITIALIZING OK
NAMES STORED OK
PASSWORD OK
SPEAK. SERIAL OK
SIMPLEBUS
1. Calling a user
` standby mode
1A. enter the user code (e.g. 2)
Setting the type of remote connection
Use
Setting the language
SELECT LANGUAGE
*ITALIANO
ENGLISH
FRANCAIS
OK OK
SCROLL ESC
2. press or to conrm
1. to display the language that you want to select, scroll
through the list using
DEFAULT= Italiano
SELECT LANGUAGE
ITALIANO
*ENGLISH
FRANCAIS
OK OK
SCROLL ESC
» * indicates language selected
3. to exit, press
When you switch the system on, you will be asked
to select the desired language.
2. press
or
to conrm
IMPORTANT: For downloading in RS485 mode,
see diagram on page 35.
CAUTION: The download via USB function is not
available in ViP mode.
IMPORTANT: To avoid malfunctions: during
download in USB mode, the keypad must not be
powered by an external source.
In SIMPLEBUS/SIMPLEBUS TOP mode (see page
13) and with USB connected: when you switch the
system on, you will be asked to select the type of
download
1. To select the type of download, scroll through
the list using
» * indicates the type of download selected
3. to exit, press
TYPE OF DOWNLOAD
*OFF
USB
RS485
OK OK