Manual

13
2.6 Setting Dome Camera Protocol and Video
If a dome camera is to be installed with the keyboard controller, select the default protocol.
Consult service personnel if a dome camera is installed with device other than a keyboard
controller.
S2
You can set Protocol with dip switch D2, D3 and D4 in S2.
S2
D2 D3 D4
P
ROTOCOL
OFF OFF OFF
F2, F2E, Pelco-P, Pelco-D : default
OFF OFF
ON
F2, F2E
OFF
ON ON
Pelco-P, Pelco-D
You can set Baud Rate with dip switch D5 and D6 in S2.
S2
D5 D6
B
AUD
R
ATE
OFF OFF 2400 bps
OFF
ON
4800 bps
ON
OFF
9600 bps : default
ON ON
19200 bps
Figure 5 – Protocol, Baud rate Selection Switches