Manual

23
4.1.1 Event operations
Select the Device tab.
Select a device from the device tree.
Select an event type to set up from the combo-box.
Enable/Disable the selected event operation from the list.
Set up the event operations.
If you want to apply the same operations to other devices, select the Apply to button and select
device(s)/group(s).
Table 8 Device Event Operations
Event Operations Options Settings
Enable Yes/No Enable/Disable the event operations
View Channel Dwell Time Amount of time to display the event channel
Live View What view to show the event channel on Live1,
Live2, Emap and All.
View Layout Dwell Time Amount of time to show the layout
Layout What layout to show in the Event view
Sound Enable Enable/Disable the sound
File Select the sound file, otherwise the default sounds
will be automatically be initiated
Record Dwell Time Event Recording independent on schedule
Preset Preset ID In the case of PTZ, move the preset
Manual Trigger Trigger ID If it supports manual trigger, it will trigger
Run External Exe File Execute an external application
Event Relay Relay Out List Select the Relay Out
* The Record operation in the device event list only affects the recording schedule. For example, if there
is a device which is configured that there is no recording (time/event) schedule from 9:00 AM to 10:00 AM.
If an event which operation is recording, is happened during that time, it would be recorded as configured
with above setting value.
* The Relay Out has the similar configurations of the device event. Please do not configure relay chains.
(For example, a manual trigger of device A relays a manual trigger of device B. And manual trigger of
device B relays manual trigger of device A. It makes relay chain continuously. It MAY cause endless event
operations)
* The View Channel option needs event channel setting on the Live1, Live2 and Emap. If there is no event
channel setting on them, it will not work.
* The Dwell Time values of the View Channel and View Layout have a minimum time out of 5 sec. If
another event occurs, the view channel and layout MAY be preemptive even though the value is over 5
seconds.