Product Overview

Multi-Zone Heat Pumps
18,000 to 42,000 BTUH
Mix and match indoor units to best
meet comfort requirements
InverterFlex
®
SERIES
InverterFlex
®
Systems condition up to ve rooms
Outdoor Unit
Ceiling Cassette
Floor & Ceiling Console
Ducted Unit
High Wall Mount
Floor & Wall Console
Our InverterFlex
®
multi-zone units let you condition one up to
ve rooms with just one outdoor unit (depending on model).
The contractor can design a system that best meets the load
requirements of each room being conditioned because indoor air
handlers can be mixed and matched—all ve types of units shown
can be used in the same installation.
These 9,000, 12,000, 18,000, 21,000 and 24,000 BTUH indoor
units can be mixed, up to the point that their combined capacity
reaches the total allowable system capacity—see the chart inside.
All units must operate in the same mode except “fan” only can
always be selected. True zone control is possible because each air
handler operates independently and has its own wireless remote.
InverterFlex
®
models incorporate all the advantages of twin
rotary inverter compressor technology. The compressor speed is
variable, depending on the load demand. Most of the time the unit
runs at low frequency, saving energy while maintaining comfort,
but ramping up to higher frequency when needed. Temperature
uctuations and compressor on/off cycling are eliminated, and
indoor air quality is enhanced because air is constantly being
pulled through the lter and dehumidied.
InverterFlex
®
systems are also great for larger spaces such as
fellowship halls and commons areas: install multiple units for quiet,
efcient, easily controlled comfort.
Features
(Varies according to type of indoor unit)
nAuto Swing—Continually adjusts air
direction for a gentle, breeze-like effect
preferred by most people
nMultiple Modes—Cooling, heating, fan
only, dehumidication only, plus:
• Sleep mode
• 24-hour timer
• Turbo mode
• Auto mode
nIntelligent Pre-Heating—Enhances
comfort by preventing cold air blow
nAuto Operation—Automatically selects
the mode required to maintain a constant
temperature/humidity level
n“Follow” Function—Senses temperature
at the remote and adjusts air ow for
comfort and efciency at its location
n Superior Filtration—Air lters are
designed to help enhance indoor air quality
nAuto Defrost—Defrosts only when
necessary to save energy, limit downtime
nSelf-Clean Mode—Dries out indoor unit
when not in use to prevent mold growth
nLow Ambient Operation
'XHWRRQJRLQJSURGXFWLPSURYHPHQWVVSHFLILFDWLRQVDQGGLPHQVLRQVDUH
VXEMHFWWRFKDQJHDQGFRUUHFWLRQZLWKRXWQRWLFHRULQFXUULQJREOLJDWLRQV'HWHUPLQLQJWKH
DSSOLFDWLRQDQGVXLWDELOLW\IRUXVHRIDQ\SURGXFWLVWKHUHVSRQVLELOLW\RIWKHLQVWDOOHU
$GGLWLRQDOO\WKHLQVWDOOHULVUHVSRQVLEOHIRUYHULI\LQJGLPHQVLRQDOGDWDRQWKHDFWXDOSURGXFW
SULRUWREHJLQQLQJDQ\LQVWDOODWLRQSUHSDUDWLRQV
7KLUGSDUW\LQFHQWLYHDQGUHEDWHSURJUDPVKDYHSUHFLVHUHTXLUHPHQWVDVWRSURGXFWSHUIRUPDQFH
DQGFHUWLILFDWLRQ$OOSURGXFWVPHHWDSSOLFDEOHUHJXODWLRQVLQHIIHFWRQGDWHRIPDQXIDFWXUH
KRZHYHUFHUWLILFDWLRQVDUHQRWQHFHVVDULO\JUDQWHGIRUWKHOLIHRIDSURGXFW
7KHUHIRUHLWLVWKHUHVSRQVLELOLW\RIWKHDSSOLFDQWWRGHWHUPLQHZKHWKHUDVSHFLILF
PRGHOTXDOLILHVIRUWKHVHLQFHQWLYHUHEDWHSURJUDPV
CA-VFH-15A
SP 1M 4/15
In recent years, heating and cooling manufacturers have
made signicant advances in the efciency of systems
in terms of energy usage. This is an especially important
purchase consideration as fuel prices continue to rise.
Cooling efciency is measured by a Seasonal Energy
Efciency Ratio (SEER) rating. The higher the number,
the more efcient the equipment. All Comfort-Aire
InverterFlex
® systems are rated at 16 SEER.
Heating efciency is shown by a Heating Season
Performance Factor (HSPF). This is an estimate
calculated by dividing the seasonal heating output by the
seasonal power consumption in watts. InverterFlex units
are rated at 8.20 HSPF, which is considered very good.
All heating and cooling equipment comes with an
Energy Guide label which shows the estimated energy
usage—you can use these labels to compare equipment
efciency. Your dealer can help you determine which
system is best for you, taking into account a number of
factors including the average number of yearly cooling
and heating days in your area of the country, in addition
to your individual needs.
When you buy Comfort-Aire products, you’re purchasing
the peace of mind that comes from dealing with a
company that has a long track record of success. We have
a well-deserved reputation not only for quality products,
but also for standing behind these products with excellent
warranty and support programs. Also, you’ll nd our
web site is a convenient resource: owners’ manuals can
be downloaded and your installer can access technical
information and service manuals.
WHAT DO WE MEAN BY
ENERGY EFFICIENCY?
READY TO BUY?
SOME THINGS TO CONSIDER
Zones Indoor Units* Total BTUH
A-VFH18DA
1-2 Units
9K 9,000
12K 12,000
18K 18,000
21K 21,000
9K + 9K 18,000
9K + 12K 21,000
A-VFH24TA
1, 2 or 3
Units
12K 12,000
18K 18,000
21K 21,000
24K 24,000
9K + 9K 18,000
9K + 12K 21,000
9K + 18K 27,000
9K + 21K 30,000
12k + 12K 24,000
12K + 18K 30,000
12K + 21K 33,000
18K + 18K 36,000
9K + 9K + 9K 27,000
9K + 9K + 12K 30,000
9K + 12K + 12K 33,000
9K + 9K +18K 36,000
A-VFH30QA
1, 2, 3 or 4
Units
18K 18,000
21K 21,000
24K 24,000
9K + 9K 18,000
9K + 12K 21,000
9K + 18K 27,000
9K + 21K 30,000
12k + 12K 24,000
12K + 18K 30,000
18K + 18K 36,000
18K + 21K 39,000
9K + 9K + 9K 27,000
9K + 9K + 12K 30,000
9K + 12K + 12K 33,000
9K + 9K +18K 36,000
9K + 9K + 21K 39,000
9K + 12K + 18K 39,000
12K + 12K + 12K
36,000
12K + 12K + 18K 42,000
9K + 9K + 9K + 9K 36,000
9K + 9K + 9K + 12K 39,000
9K + 9K + 12K + 12K 42,000
18K 18,000
21K 21,000
24K 24,000
9K + 24K 33,000
Zones Indoor Units* Total BTUH
9K + 9K 18,000
9K + 12K 21,000
9K + 18K 27,000
12k + 12K 24,000
12K + 18K 30,000
12K + 24K 36,000
18K + 18K 36,000
18K + 24K 42,000
24K + 24K 48,000
9K + 9K + 9K 27,000
9K + 9K + 12K 30,000
9K + 9K + 18K 36,000
9K + 9K +24K 42,000
9K + 12K + 12K 33,000
9K + 12K + 18K 39,000
9K + 12K + 24K 45,000
9K + 18K + 18K 45,000
9K + 18K + 24K 51,000
12K + 12K + 12K 36,000
12K + 12K + 18K 42,000
12K + 12K + 24K 48,000
12K + 18K + 18K 48,000
18K + 18K + 18K 54,000
9K + 9K + 9K + 9K 36,000
9K + 9K + 9K + 12K 39,000
9K + 9K + 9K + 18K 45,000
9K + 9K + 9K + 24K 51,000
9K + 9K + 12K + 12K 42,000
9K + 9K + 12K + 18K 48,000
9K + 12K + 12K + 12K 45,000
9K + 12K + 12K + 18K 51,000
12K + 12K + 12K + 12K 48,000
A-VFH42PA
1, 2, 3, 4 or
5 Units
21K 21,000
24K 24,000
9K + 12K 21,000
9K + 18K 27,000
9K + 21K 30,000
9K + 24K 33,000
12K + 12K 24,000
12K + 18K 30,000
12K + 21K 33,000
12K + 24K 36,000
18K + 18K 36,000
18K + 24K 42,000
24K + 24K 48,000
9K + 9K + 9K 27,000
9K + 9K + 12K 30,000
9K + 9K + 18K 36,000
Zones Indoor Units* Total BTUH
A -VFH42PA
1, 2, 3, 4 or
5 Units
9K + 9K + 21K 39,000
9K + 9K +24K 42,000
9K + 12K + 12K 33,000
9K + 12K + 18K 39,000
9K + 12K + 24K 45,000
9K + 18K + 18K 45,000
9K + 18K + 24K 51,000
9K + 24K + 24K 57,000
12K + 12K + 12K 36,000
12K + 12K + 18K 42,000
12K + 12K + 24K 48,000
12K + 18K + 18K 48,000
12K + 18K + 21K 51,000
12K + 18K + 24K 54,000
12K + 24K + 24K 60,000
18K + 18K + 18K 54,000
18K + 18K + 24K 60,000
9K + 9K + 9K + 9K 36,000
9K + 9K + 9K + 12K 39,000
9K + 9K + 9K + 18K 45,000
9K + 9K + 9K + 21K 48,000
9K + 9K + 9K + 24K 51,000
9K + 9K + 12K + 12K 42,000
9K + 9K + 12K + 18K 48,000
9K + 9K + 12K + 24K 54,000
9K + 9K + 18K + 18K 54,000
9K + 9K + 18K + 24K 60,000
9K + 12K + 12K + 12K 45,000
9K + 12K + 12K + 18K 51,000
9K + 12K + 12K + 24K 57,000
9K + 12K + 18K + 18K 57,000
9K + 18K + 18K + 18K 63,000
12K + 12K + 12K + 12K 48,000
12K + 12K + 12K + 18K 54,000
12K + 12K + 12K + 24K 60,000
12K + 12K + 18K + 18K 60,000
9K+9K+9K+9K+9K 45,000
9K+9K+9K+9K+12K 48,000
9K+9K+9K+9K+18K 54,000
9K+9K+9K+9K+24K 60,000
9K+9K+9K+12K+12K 51,000
9K+9K+9K+12K+18K 57,000
9K+9K+9K+18K+18K 63,000
9K+9K+12K+12K+12K 54,000
9K+9K+12K+12K+18K 60,000
9K+12K+12K+12K+12K 57,000
9K+12K+12K+12K+18K 63,000
12K+12K+12K+12K+12K 60,000
The total capacity for ALL indoor units cannot exceed
150% of the stated condenser capacity. For best
performance, the indoor units’ total capacity should be
100% or less of the condenser capacity. When a system
is sized beyond 100% of the condenser capacity, the
Indoor Unit Mix ‘n’ Match Possibilities
compressor may not provide full capacity for all indoor
units: sizing above 100% is generally specied when one
or more of the indoor units will not be in use most of the
time. Also, the total capacity for ALL indoor units cannot be
less than 50% of the condenser’s capacity.
5
Wireless remote
included with
each indoor unit
Other combinations possible with B-VFH21DA-1.
:HOOZRUWK$YH-DFNVRQ0,3KZZZFRPIRUWDLUHFRP
A-VFH36QA
1, 2, 3 or 4
Units
A-VFH36QA
1, 2, 3 or 4
Units