VFH InverterFlex
®
- Indoor Ductless Mini-Split Heat Controller
Features and functions of wireless remote control
SLEEP
SLEEP button
Operation of wireless remote control

The sleep program allows for the most comfortable
conditions while you sleep, as body temperatures change.
To activate the sleep mode, press the sleep mode button.
There are (3) different programmed settings to choose
from Sleep 1 ( 1), Sleep 2 ( 2), and Sleep 3 ( 3)
described below. To cancel the Sleep mode, press the
Sleep mode button and cycle through options 1, 2, and 3,
until the Sleep icon disappears from the display.
The Sleep function can not be enabled when the
unit is in Fan or Auto mode. Sleep 1 can only be selected
when the unit is in Cool or Dry mode. When Sleep mode
is enabled, Quiet mode is also automatically enabled
in conjunction. However, Quiet mode can be turned off
manually.

When Sleep 1 is activated while the unit is in Cool or Dry
mode, the unit’s set temperature will increase 1-2 degrees
during the rst hour, then after 2 hours it will decrease
by 3-4 degrees more and then continue to run at this
temp. When Sleep mode is activated while the unit is in
Heat mode, the unit will operate by decreasing the set
temperature by 1-2 degrees the rst hour and then by
3-4° degrees the next 2 hours. Then the unit will continue
to run at this temperature.

Sleep 2 operates differently than Sleep 1, as it takes into
account the set temperature.

• When the initial set temperature is between 61°F-74°F
(16°C-23°C), the temperature will increase 1-2 degrees
every hour until it reaches a 5-6 degree difference. It will
operate at this setting for (7) hours. After 7 hours, the
temperature will decrease 1-2 degrees and continue to
operate under this condition.
• When the initial set temperature is between 75°F-81°F
(24°C-27°C), the temperature will increase 1-2 degrees
every hour until a 3-4 degree difference is achieved.
This will be maintained for (7) hours, after which another
1-2 degree decrease will take place. Then the unit will
continue to operate under this condition.