Owner’s Manual SVH Series Inverter Single Zone Ductless Mini-Split SVH09SA-0 SVH09SA-1 SVH12SA-0 SVH12SA-1 SVH18SA-1 SVH24SA-1 www.marsdelivers.
Owner’s Manual - SVH 09/12/18/24 Series Table of Contents Owner’s Manual 0 Safety Precautions.......................................................04 1 Unit Specifications and Features..............................06 SAFETY FIRST 2 Manual Operation (Without Remote)................
Owner’s Manual - SVH 09/12/18/24 Series 3 Care and Maintenance.....................................................12 4 Troubleshooting...................................................................
Owner’s Manual - SVH 09/12/18/24 Series Safety Precautions Safety Precautions Read Safety Precautions Before Installation Incorrect installation due to ignoring instructions can cause serious damage or injury. The seriousness of potential damage or injuries is classified as either a WARNING or CAUTION. This symbol indicates that ignoring instructions may cause death or serious injury.
Owner’s Manual - SVH 09/12/18/24 Series Safety Precautions CLEANING AND MAINTENANCE WARNINGS • • • Turn off the device and disconnect the power before cleaning. Failure to do so can cause electrical shock. Do not clean the air conditioner with excessive amounts of water. Do not clean the air conditioner with combustible cleaning agents. Combustible cleaning agents can cause fire or cabinet deformation.
Owner’s Manual - SVH 09/12/18/24 Series Unit Parts Front Panel Power Cable (Some Units) Remote Control Louver Display window(A) fresh defrost run timer Display window(B) Remote Holder (Some Units) fresh defrost run timer "fresh" when FRESH feature is activated (some units) "run" when the unit is on. "timer" when TIMER is set. " " Not available for all units. ECO function(some units) is activated, the ,When,illuminates gradually one by one as --- --set temperature -- ...... in one second interval.
Owner’s Manual - SVH 09/12/18/24 Series Achieving Optimal Performance Unit Specifications and Features Optimal performance for the COOL, HEAT, and DRY modes can be achieved in the following temperature ranges. When your air conditioner is used outside of these ranges, certain safety protection features will activate and cause the unit to perform less than optimally.
Owner’s Manual - SVH 09/12/18/24 Series For a detailed explanation of each function, refer to the Remote Control Manual. • Air Filter Reminders (some units) Other Features • Auto-Restart If the unit loses power, it will automatically restart with the prior settings once power has been restored. • Anti-mildew (some units) When turning off the unit from COOL, AUTO (COOL), or DRY modes, the air conditioner will continue operate at very low power to dry up condensed water and prevent mildew growth.
Owner’s Manual - SVH 09/12/18/24 Series Unit Specifications and Features • Setting Angle of Air Flow Setting vertical angle of air flow While the unit is on, use the SWING/DIRECT button to set the direction (vertical angle) of airflow. 1. Press the SWING/DIRECT button once to activate the louver. Each time you press the button, it will adjust the louver by 6°. Press the button until the direction you prefer is reached. Ra 2.
Owner’s Manual - SVH 09/12/18/24 Series Unit Specifications and Features • Sleep Operation The SLEEP function is used to decrease energy use while you sleep (and don’t need the same temperature settings to stay comfortable). This function can only be activated via remote control. Press the SLEEP button when you are ready to go to sleep. When in COOL mode, the unit will increase the temperature by 1°C (2°F) after 1 hour, and will increase an additional 1°C (2°F) after another hour.
Owner’s Manual - SVH 09/12/18/24 Series Manual Operation (Without Remote) How to operate your unit without the remote control 2 CAUTION Manual Operation (Without Remote) The manual button is intended for testing purposes and emergency operation only. Please do not use this function unless the remote is lost and it is absolutely necessary. To restore regular operation, use the remote control to activate the unit.
Owner’s Manual - SVH 09/12/18/24 Series 3 Care and Maintenance Cleaning Your Indoor Unit BEFORE CLEANING OR MAINTENANCE ALWAYS TURN OFF YOUR AIR CONDITIONER SYSTEM AND DISCONNECT ITS POWER SUPPLY BEFORE CLEANING OR MAINTENANCE. CAUTION 6. Rinse the filter with fresh water, then shake off excess water. 7. Dry it in a cool, dry place, and refrain from exposing it to direct sunlight. 8. When dry, re-clip the air freshening filter to the larger filter, then slide it back into the indoor unit. 9.
Owner’s Manual - SVH 09/12/18/24 Series Maintenance – Long Periods of Non-Use CAUTION • • • • Before changing the filter or cleaning, turn off the unit and disconnect its power supply. When removing filter, do not touch metal parts in the unit. The sharp metal edges can cut you. Do not use water to clean the inside of the indoor unit. This can destroy insulation and cause electrical shock. Do not expose filter to direct sunlight when drying. This can shrink the filter.
Owner’s Manual - SVH 09/12/18/24 Series 4 Troubleshooting SAFETY PRECAUTIONS If ANY of the following conditions occurs, turn off your unit immediately! • The power cord is damaged or abnormally warm • You smell a burning odor • The unit emits loud or abnormal sounds • A power fuse blows or the circuit breaker frequently trips • Water or other objects fall into or out of the unit DO NOT ATTEMPT TO FIX THESE YOURSELF! CONTACT AUTHORIZED SERVICE PROVIDER IMMEDIATELY! Common Issues The following problems ar
Owner’s Manual - SVH 09/12/18/24 Series Issue Possible Causes A rushing air sound may occur when the louver resets its position. The indoor unit makes noises A squeaking sound may occur after running the unit in HEAT mode due to expansion and contraction of the unit’s plastic parts. Low hissing sound during operation: This is normal and is caused by refrigerant gas flowing through both indoor and outdoor units.
Owner’s Manual - SVH 09/12/18/24 Series Troubleshooting When troubles occur, please check the following points before contacting a repair company.
Owner’s Manual - SVH 09/12/18/24 Series Problem The unit is not working The unit starts and stops frequently Poor heating performance Indicator lamps continue flashing Troubleshooting Error code appears in the window display of indoor unit: • E0, E1, E2… • P1, P2, P3… • F1, F2, F3… Possible Causes Solution Power failure Wait for the power to be restored The power is turned off Turn on the power The fuse is burned out Replace the fuse Remote control batteries are dead Replace batteries The U
Owner’s Manual - SVH 09/12/18/24 Series LIMITED EXPRESS WARRANTY DURATION OF WARRANTY & REGISTRATION Congratulations on purchasing your new HVAC equipment. It’s been designed for long life and reliable service, and is backed by one of the strongest warranties in the industry. Your unit automatically qualifies for the warranty coverage listed below, providing you keep your proof of purchase (receipt) for the equipment and meet the warranty conditions.
Owner’s Manual - SVH 09/12/18/24 Series 19
Owner’s Manual - SVH 09/12/18/24 Series 'XH WR RQJRLQJ SURGXFW LPSURYHPHQWV VSHFLILFDWLRQV DQG GLPHQVLRQV DUH VXEMHFW WR FKDQJH DQG FRUUHFWLRQ ZLWKRXW QRWLFH RU LQFXUULQJ REOLJDWLRQV 'HWHUPLQLQJ WKH DSSOLFDWLRQ DQG VXLWDELOLW\ IRU XVH RI DQ\ SURGXFW LV WKH UHVSRQVLELOLW\ RI WKH LQVWDOOHU $GGLWLRQDOO\ WKH LQVWDOOHU LV UHVSRQVLEOH IRU YHULI\LQJ GLPHQVLRQDO GDWD RQ WKH DFWXDO SURGXFW SULRU WR EHJLQQLQJ DQ\ LQVWDOODWLRQ SUHSDUDWLRQV ,QFHQWLYH DQG UHEDWH SURJUDPV KDYH SUHFLVH UHTXLUHPHQWV DV WR SURGXF