Installation Instructions

Portable Cooling 8,000 to 10,000 BTUH
10,000 to 12,000 BTUH
FEATURES
• Forhorizontalslidingorcasement
windows,tsopening20
5
/16”to
39
7
/16”high,startingat15
1
/2”wide
• Electroniccontrolsandremote
• Four-wayadjustableairdirection
• Energysavermodeand24-hour
on/offtimer,autorestart
SPECIFICATIONS
CD-121L 12,000 BTUH
Nominal
CoolingCapacityBTUH 12,000
Approx.Sq.Ft.Cooling 450-550
EER 9.5
HeatingCapacity
BTUH(electric)
N/A
PowerSupply 115V60Hz
HumidityRemovalPts/Hr 2.54
VentilationControl Yes
FanOnly Yes
FanSpeedsCool/Fan 3/3
AirDeliveryMax.CFM 312
dBLevel(hi/med/low) 61/59/56
AmpsCooling 11.6
AmpsHeating N/A
MaximumFuseSize 15A
PowerCord
15AParallel
NEMA5-15P
Slide-OutChassis No
WindowMountingKit Yes
RemoteControl Yes
In-HomeService Yes
ShippingWeight(lbs.) 91
Dimensions(in.) Height
20
15
/16
 Width
14
5
/8
 Depth
23
1
/2
Casement/Slider
FEATURES
• Forhorizontalslidingorcasement
windows,tsopening20
5
/16”to
39
7
/16”high,startingat15
1
/2”wide
• Electroniccontrolsandremote
Four-wayadjustableairdirection
• Energysavermodeand24-hour
on/offtimer,autorestart
CD-101L 10,000 BTUH
SPECIFICATIONS
Nominal
CoolingCapacityBTUH 10,000
Approx.Sq.Ft.Cooling 400-450
EER 9.5
HeatingCapacity
BTUH(electric)
N/A
PowerSupply 115V60Hz
HumidityRemovalPts/Hr 2.32
VentilationControl Yes
FanOnly Yes
FanSpeedsCool/Fan 3/3
AirDeliveryMax.CFM 312
dBLevel(hi/med/low) 61/59/56
AmpsCooling 10.0
AmpsHeating N/A
MaximumFuseSize 15A
PowerCord
15AParallel
NEMA5-15P
Slide-OutChassis No
WindowMountingKit Yes
RemoteControl Yes
In-HomeService Yes
ShippingWeight(lbs.) 85
Dimensions(in.) Height
20
15
/16
 Width
14
5
/8
 Depth
23
1
/2
Installation Tips
Casement/Slider Windows
Thesewindowswhichslideopento
thesideoropenoutwardrequirea
differenttypeofwindowaircondi-
tioner.OurCDmodelsareidealfor
casementorsliderwindows.The
windowcancloseontothesidesof
theunit,andasupportplatformis
included.Aplasticwindowllerpanel
isincludedwiththeunit—itcanbe
cuttosizeandtsintoanadjustable
windowpanelframe.Foracasement
window,thewindowcrankmustbe
removed.
Slider Window
Fillerpaneltsintoframethatis
installedabovetheunit.
Casement Window
Windowopensoutwardorthe
exteriorpanemayberemoved.
Crankmechanismisremoved.
Always follow the
installation instructions
included with the unit.
12