Service Questions: Contact Comfort Aire at (517) 787-2100 Sales Inquiries: Contact Sylvane at (800) 934-9194 or visit sylvane.com OWNER’S MANUAL Room Air Heat Pump with R-410A: RAH-123G Heat Controller, Inc. • 1900 Wellworth Ave. • Jackson, MI 49203 • (517)787-2100 • www.heatcontroller.
Room Air Heat Pump with R-410A Owner’s Manual Heat Controller, Inc. Room Air Conditioner & Heat Pump Use and Care Manual Contents Introduction............................................................. .................................................................. 11 Introduction. SafetyInformation................................................... Information ....................................................... 11 Safety NormalCare Care && Maintenance...................................
Heat Controller, Inc. Room Air Heat Pump with R-410A Owner’s Manual OWNER'S PRODUCT IDENTIFICATION WARNING To preventheat heatrelated related illness or death, do To prevent illness or death, not useuse this device unattended cooling do not this devicefor unattended. Failure of anor unattended air conditioner of persons animals unable to react to may result in extreme heatof inunattended area product failure.
Room Air Heat Pump with R-410A Owner’s Manual Unit Plug Type Receptacle Required page included with this manual or in the mounting kit assembly. Follow these instructions carefully. Keep these instructions with this manual for future reference. Your unit will be one of the following three designs: Circuit Rating, Voltage Breaker, Time Rating On Delay Fuse Nameplate NEMA No. 5-15P NEMA No. 5-15R 125V-15AMP 115V NEMA No. 6-15P NEMA No. 6-15R 250V-15AMP 230/208V rated at 12 amperes or less NEMA No.
Room Air Heat Pump with R-410A Heat Controller, Inc. Note: greatly reduced Note: The Thelife lifeof of your your unit unit may may be be greatly reducedifif you you live live in corrosive and/or oceanside location with salty air. Under in aasalt air or other corrosive type environment. Under these these conditions, the should unit should be removed its case conditions, the unit be removed fromfrom its case and and completely cleaned least oncea ayear. year.
Room Air Heat Pump with R-410A Owner’s Manual Heat Controller, Inc. IMPORTANT SAFETY INSTRUCTIONS WARNING: To reduce the risk of fire, electrical shock or injury when using your air conditioner, follow these basic precautions: Plug into a grounded 3 prong outlet. Do not use an extension cord. Do not remove ground prong. Unplug air conditioner before servicing. Do not use an adapter. Use two or more people to move and install air conditioner.
Room Air Heat Pump with R-410A Heat Controller, Inc. Owner’s Manual Electrical Requirements Window installation Window opening measurements: ■ 27" min. to 39" max. opening width. ■ WARNING 16¹⁄₄" min. opening height. Electrical Shock Hazard Plug into a grounded 3 prong outlet. A Do not remove ground prong. Do not use an adapter. B Do not use an extension cord. Failure to follow these instructions can result in death, fire, or electrical shock. A. 27" min. B. 16¹⁄₄" min.
Room Air Heat Pump with R-410A Owner’s Manual WARNING Recommended grounding method This air conditioner must be grounded. This air conditioner is equipped with a power supply cord having a grounded 3 prong plug. To minimize possible shock hazard, the cord must be plugged into a mating, grounded 3 prong outlet, grounded in accordance with all local codes and ordinances.
Room Air Heat Pump with R-410A Heat Controller, Inc. Owner’s Manual INSTALLATION INSTRUCTIONS Unpacking 3. Remove front panel by removed 2 phillips screws on both bottom left right sides of front. 3A: Remove both knobs from control panel. WARNING Excessive Weight Hazard 4. Pull on handle to slide air conditioner out of cabinet. Place air conditioner on cardboard. Use two or more people to move and install air conditioner. Failure to do so can result in back or other injury. 5.
Room Air Heat Pump with R-410A Owner’s Manual Attach Side Curtains Heat Controller, Inc. Attach foam adhesive seal 1. Locate provided bag of screws. 2. Insert top and then bottom of right-hand curtain housing in top and bottom curtain guides on air conditioner cabinet. Attach foam adhesive seal along the bottom of the curtain bottom channel. Back View A B A B A. Curtain housing B. Foam adhesive seal Install Cabinet into Window A. Curtain housing B.
Room Air Heat Pump with R-410A Heat Controller, Inc. 4. Use a ³⁄₁₆" drill bit to drill 3 starter holes 1/2" deep through the 3 holes in the cabinet and into the windowsill. 5. Attach cabinet to windowsill with 3 - #10 x 1/2" pan-head Phillips screws. Owner’s Manual 2. Insert one of the #10 x ³⁄₄" round-head screws through hole and into lower window sash. Insert one of the #10 x ³⁄₄" round-head screws through threaded hole in top of curtain and one in bottom of curtain. A B B A A A.
Room Air Heat Pump with R-410A Owner’s Manual General Operating Instructions While operation of all units is similar, controls vary slightly from model to model. Operating Controls section shows control panel of unit purchased and gives detailed information about operation of controls. Heat Controller, Inc. To install, remove the unit chassis from the outer case. Insert the condensate drain cup through the recessed ½” hole on the back center of the outer case.
Room Air Heat Pump with R-410A Heat Controller, Inc. Operating Controls(For Electronic ) O perating Controls(For Electronicunits units) Operating your air conditioner properly helps you to obtain the best possible results. This section explains proper air conditioner operation. IMPORTANT: ■ If you turn off the air conditioner, wait at least 3 minutes before turning it back on. This prevents the air conditioner from blowing a fuse or tripping a circuit breaker.
Room Air Heat Pump with R-410A Owner’s Manual Timer/Delay OFF—the When the air conditioner Delay OFF—When air conditioner is on, is on, Heat Controller, Inc. Cooling Descriptions it can be set to automatically turn off in 0.5 to 24 hours. For Normal Cooling—Select the Cool mode and High or Med fan with a middle set temperature. How to set: For Maximum Cooling—Select the Cool mode and High fan with a lower set temperature. Press the Timer Delay 0.
Heat Controller, Inc. Room Air Heat Pump with R-410A Owner’s Manual Troubleshooting Before Calling Service WARNING To reduce the risk of electric shock, personal injury, or death, turn the fan control to the off position and remove the unit plug from the wall outlet before doing any inspection or maintenance work. The following is a list of problems that are sometimes encountered when using a room air conditioner. Possible cause and suggested remedies are given for each problem.
Service Questions: Contact Comfort Aire at (517) 787-2100 Sales Inquiries: Contact Sylvane at (800) 934-9194 or visit sylvane.