Owner`s manual

Owners Manual Room Air Heat Pump with R-410A Heat Controller, Inc.
4
4
Front Grille and Filter Removal
The front contains a removable grille that provides easy
access to the air filter. To clean the filter use one of the
following methods for filter removal:
METHOD ONE
Grasp filter handle and slide filter out of unit.
Optional Air Filter Installation
Remove air filter from plastic bag. Insert three tabs
on right side of filter into three slots on filter frame. Carefully
bow middle of filter until two tabs on filter can be inserted into
two slots on filter frame. Relax bow.
Reinstall air filter and grille by reversing removal procedure.
Front Grille and Cabinet Cleaning
Grille and cabinet may be cleaned with warm water and mild
soap or detergent. Cleaning and polishing compounds are
not recommended, as they may damage plastic surfaces.
Air Filter Cleaning
A dirty air filter reduces operating efficiency of unit. Filter
should be inspected at least once every week during opera-
tion. Clean filter with vacuum cleaner or wash in warm water
and mild detergent. Filter should be thoroughly dried before
replacing in unit. Do not operate unit without filter in place.
Fan Motor Care
The fan motor is permanently lubricated for long life. There is
no need to oil the motor.
Slide-out Chassis Removal from Outer Case
1. Remove front grille by sliding grille to left and pulling out.
2. Remove air filter by sliding to left.
3. Remove four screws holding plastic front to unit and
remove front.
4. If the unit has a screw holding the basepan clip to the
chassis, remove the screw.
To reduce the risk of personal injury be
sure to have sufficient help when moving
your unit. A room air conditioner can
weigh between 70 and 240 pounds.
CAUTION
5. Using basepan handle, pull chassis straight out, slowly
and evenly, until approximately 9-12 inches extends
To reduce the risk of personal injury, be
sure to have sufcient help when moving
your unit. A room air conditioner can be
excessivley heavy.