SPECIFICATIONS:
Please refer to the correct model for specications:
NOTE: Receptacles, Timers and GFCI Plugs only available on select models.
PRODUCT OVERVIEW:
OPERATING INSTRUCTIONS:
The air mover is ready to use, out of the box – no assembly
required. It is intended to move air and dry oors, walls, furniture,
crawl spaces, basements, etc. The air mover is powerful,
durable and easy‑to‑operate, making it suitable for a variety of
applications.
1. Before plugging into an electrical outlet, make sure the air
mover does not have visible damage Place the air mover on
a stable, at, dry surface.
2. Position the air mover to the surface that needs to be dried.
This air mover is able to be used at 3 different angles for
optimal air ow.
3. Plug the power cord into the electrical outlet and turn the
switch to select the desired speed.
4. Please make sure the air mover is supervised at all times
while operating.
DAISY CHAINING:
Some models come equipped with additional receptacles on
the unit, providing the ability to connect a series of air movers
(or other appliances) together using a single connection at the
outlet. These air movers/appliances will work whether the air
mover is on or off. Please note that the total amperage must
be lower than the 12 amps on the circuit breaker.
If the air mover is plugged in and stops working, press the
RESET button to reset the circuit.
GFCI PLUG:
Some models come equipped with a GFCI plug.
A ground fault circuit interrupter (GFCI) plug will automatically
shut off power directly at the power source when it detects an
electrical fault.
If the plug trips, push the reset button on the GFCI plug to get
it working again.
To test your GFCI plug press the button labeled 'test'. If the air
mover stops working, your GFCI is working properly. To make
it active again, simply press the 'reset' button.
TIMER FUNCTION:
Some models have a timer function that will turn the air mover
OFF after a specied time.
Turn the TIMER knob to set the preferred time from 1 minute
up to 180 minutes (3 hours), or anywhere in between. The
TIMER function will count down the time and turn the air mover
OFF once set time is reached.
ADJUSTABLE ANGLES:(SELECT
MODELS)
MODEL CZBC141 CZBC131G CZBC121T CZBC101T
Power 1/4 HP 1/3 HP 1/2 HP 1 HP
Amp 1.8 2.8 4.5 6.9
Speeds 3 3 3 3
Daisy Chain Yes No No No
Plug Type Grounded GFCI Grounded Grounded
Timer No No Yes Yes
Cord
Length
14 AWG
10 ft.
18 AWG
20 ft.
18 AWG
20 ft.
18 AWG
25 ft.
Overheat
Protection
Thermally
Protected
Thermally
Protected
Thermally
Protected
Thermally
Protected
Rated Airow 800 CFM 1250 CFM 1500 CFM 1900 CFM
Tilt Angle 0°, 45°, 90° 0°, 45°, 90° 0°, 45°, 90°
Weight 10.9 lbs. 25.6 lbs. 26.5 lbs. 34 lbs.
Reset Button
45°
90°
Receptacle (Select Models)
Rubber Feet
Receptacle (Select Models)
3 Hour Timer
Convenient Carry
Handle & Cord Wrap
Speed Selector
Switch
Grounded Cord or GFCI Plug
(Select Models)
This air mover has 3 operating angles that allow you to
blow air at 0, 45 and 90 degree angles.