Installation Guide

Operators Manual
HP54 Pellet Stove
~ 27 ~
Increasing the exhaust voltage, and thereby increasing the
amount of air in the burn pot, will also assist in burning lower-
quality fuels that may otherwise cause unwanted buildup.
NOTE: Be sure to visually watch the burn rate if the
combustion voltage is decreased, as to not cause pot
overloading. Exhaust voltage should ONLY be adjusted to get
the optimum performance out of the fuel you are burning.
4) Move to “Blower voltage ”, set the Correct value.
The blower voltage (controlling the room fan) can be turned up
or down for each power level to regulate the amount of heat
circulated into a room during stove operation. Some fuels
radiate heat better than others. You have the ability to speed
up or slow down the room fan to extract the optimum amount
of heat without blowing cold air. Increasing the blower
voltage causes the convection motor to run faster, extracting
more heat from the unit.
NOTE: If having issues with the stove overtemping in any
setting, increase the blower voltage.
Decreasing the blower voltage allows you to slow the exchange
of heat from the stove so it blows less cold air
Set Ash Cleaning Cycle
Select the “Set Ash Cleaning Cycle”, and press enter. This
will take you into the “AshCleaning” screen. SEE FIGURE 28.
AshCleaning level:H01
1:
Time span: -- Min
2:
Duration:--Sec
Smart Ash Cleaning: ON
Light Medium Heavy
Figure 28
Ash clean cycle include the Time Span (** Min) and Duration
time(**Sec)
During The Duration time period ,the feed is stop and the
exhaust fan funning at full speed. The period between two
lasting time is the Span Time. It can be adjust from 30min to
60 min.
Smart Ash cleaning is an automatic Ash cleaning cycle. It
has 3 setting: light ,medium ,heavy.
Set ECO
Select the “Eco”, and press enter. This will take you into the
“Eco” screen. SEE FIGURE 29.
If the ECO is on, the stove will fire off when the room
temperature get to the call to temperature. And when the
thermostat call for heating ,the stove start again.
IF the ECO is off, the stove will keep idle (level 1) when the
room temperature get to the call to temperature.
Set Eco
ECO:ON
Figure 29
DIAGNOSTICS
Your Stoves controller comes equipped with an on-board
diagnostics option that will let you test some components of
your stove.
NOTE: You will only be able to enter the diagnostic screen
when the stove is turned OFF.
Select the “DIAGNOSTICS”, and press enter. This will take you
into the “Diagnostic” screen. (Figure 30)
Diagnostic level:H01
Fire: Exhaust: Feed:
Blow:Limit: Vacuum:
POF:
Hopper T: 50 Room T:40
Figure 30
level: Changing the level will allow you to test the
component in the various heating power levels.
Fire :Indicates whether the ignitor is working
properly.
Exhaust: Indicates whether the combustion motor and
exhaust system is working properly.
Blower: Indicates whether the room fan/blower is
working properly.
Feeding: Indicates if the auger is properly feeding
pellets.
Limit: Indicates the hopper lid is properly shut.
Vacuum: Indicates there is sufficient vacuum and
suction.
POF : Indicates the proof of fire switch is properly
working.
Hopper T :Indicates temperature being read by over