User`s guide

8
9
1) Building Distributor: One Building distributor can be connected to up to 4
multi-entry panel units, outside distributor, floor distributor, GUARD or porter
(Dip switch setting number in a Building Distributor corresponds to its build number)
2) Floor Distributor: One floor distributor can be connectable up to 4 household
units per floor.
3) In-house Unit: A total of 2 in-house units, one MASTER unit and one SLAVE unit,
are connectable.
4) Guard (porter): From the in-house unit to the GUARD porter, call and
communication are possible.
(The GUARD porter is only capable of receiving incoming calls and CANNOT
make outgoing calls to individual rooms.)
6. Setting Room Numbers to MASTER, SLAVE Units
7. Other Product Compatibility
Setup will be established from the multi-entry panel connected to Channel 1.
In one room or household, there should only be one established MASTER
multi-entry unit. The remaining units should be set as SLAVE units.
Household
From the room number registration number registration mode, pressing the Door
Release button sets the unit as MASTER, and pressing the Extension Call button
sets the unit as SLAVE.
After completing registration of the room number, set the multi-entry unit's ID to “1”.
(If a multi-entry unit's ID is set to “0”, it is not in normal operation)
1. Setting the MASTER Unit
1) Set the ID to “0” for the multi-entry panel connected to Channel 1.
(For room number registration mode)
2) While picking up the handset of the in-house videophone, press the “Extension Call”
and the “Door Release” buttons at the same time.
3) Automatic communication is established between the multi-entry panel and
the in-house unit.
4) Then, press the “Door Release” button on the videophone while the call is being
made and an extended “bee” will sound signifying registration.
At this time, press the assigned household number from the multi-entry panel.
Three, successive, beeps will sound to confirm successful registration.
5) Once the call is ended, the registration is complete.
(Repeat this process to register other room numbers.)
6) After registration is complete for all households, set the ID for each multi-entry
panel to “1”.
2. Setting the SLAVE Unit
1) Set the ID to “0” for the multi-entry panel connected to Channel 1.
(For room number registration mode)
2) From the in-house unit, pickup the handset and press the Extension Call button
and the Door Release button at the same time.
3) Automatic communication is established between the multi-entry panel and
the in-house unit.
4) Then, press the “Extension Call” button on the videophone while the call
is being made and an extended “bee” will sound signifying registration.
At this time, press the assigned household number from the multi-entry panel.
Three, successive, beeps will sound to confirm successful registration.
5) Once the call is ended, the registration is complete.
(Repeat this process to register other room numbers.)
6) After registration is complete for all households, set the ID for each multi-entry
panel to “1”.