Item #3055 50 157 Model #CE-15 USE AND CARE GUIDE CE - 15 UNLESS OTHERWISE SPECIFIED: Questions, problems, missing Before returning NA toMEthe DA store, TE DIMENSIONSparts? ARE IN INCHES DRAWN MacroAir Techno TOLERANCES: 4/23/2018 logies call Commercial Electric Customer Service FRACTION 794 S Allen St. Sa AL .010 n Bernardino, CA CH ECK ED ANGULAR: MACH xxxx 92408 xxxx 1 BEND 1 TIT LE : TWO PLACE 8 a.m. - 7 p.m., EST, Monday - Friday, 9.01 a.m.ENG-APP 6 R.p.m.
Table of Contents I Beam/Truss . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Motor Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Safety Cable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Guy Wires. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Blades . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Electrical . . . . . . . . . . . . . . .
Safety Information READ AND SAVE THE ENTIRE MANUAL BEFORE OPERATING THE FAN. Ensure that all safety practices and instructions are followed during the installation, operation and servicing of the fan. Failure to apply these safety practices could result in death or serious injury. If you do not understand the instructions please call the Commercial Electric Customer Service. The fan installation should follow the recommendations outlined in this manual.
Safety Information SERVICE: If the fan does not operate properly using the procedures in this manual, BE CERTAIN TO REMOVE ALL POWER TO THE UNIT and contact Commercial Electric Customer Service for further assistance. Keep clear of moving parts at all times. All electrical troubleshooting and repair must be done by a qualified technician and meet all applicable codes.
Warranty Information The manufacturer extends this warranty to the original retail purchaser of its model or, if this unit is purchased and installed by a building contractor, then to the original owner of the building. No subsequent purchaser of the unit or of a building which it is installed is entitled to any of the benefits of this warranty. This product is warranted against defects in materials and workmanship for a period of two (2) years from the date of original retail purchase.
Pre-Installation PLANNING INSTALLATION Prior to installation, make sure to read the entire Use and Care Guide and observe all requirements specified. NOTE: For any application not explicitly covered in this Use and Care Guide, please consult a structural engineer.
Pre-Installation GG HH 5 Part Description Quantity AA I-Beam Bolts, Nuts, Washers BB I-Beam Clamps 2 CC I-Beam Shims 2 DD Motor Attachment Bolts, Nuts, Washers EE Safety Cable Clamps 4, 4, 8 2, 2, 4 2 FF Blade Bolts, Nuts, Washers GG Safety Retainer Link 10,10, 20 5 HH Guy Wire Clamps 8 SPACING REQUIREMENTS spacing between fans HVAC Diffuser with airflow UNDER fan at least 3 x diameter of the fans apart space from diffuser at least 1.
Pre-Installation PACKAGE CONTENTS F A E D C B Part Description Quantity A Guy Wires (4) B Fan Blades (5) C Guy Wire Band (1) D Fan Motor Unit (1) E Mount (1) F Safety Cable (1) 8
Pre-Installation FAN SPEED A NEMA 4X/IP65 B C Part Description Quantity A VFD/Control Box (1) B Cable To The Incoming Power (1) C Cable To The Motor (1) 9 HOMEDEPOT.COM Please contact 1-877-527-0313 for further assistance.
Installation – I-Beam/Steel Truss 1 Secure the I-Beam Clamp 2 Position the Top Plate 4 Center the Mount □□ Position the top plate under the I-beam so that one side of the beam is between the clamp and top plate. FOR MOUNTING TO STEEL TRUSSES OVER 3 INCHES IN WIDTH. FOR WIDTHS UNDER 3 INCHES OR IF YOU WISH TO MOUNT TO A DIFFERENT SURFACE THAN THESE LISTED HERE, CONTACT A STRUCTURAL ENGINEER.
Installation – Motor Unit 1 2 Slide in the Drop Attachment □□ Slide the drop attachment point of the frame into the drop tube of the mount, ensuring that the bolt holes line up. UNLESS OTHERWISE SPECIFIED: NAME DRAWN DIMENSIONS ARE IN INCHES TOLERANCES: CHECKED FRACTIONAL ā .010 ANGULAR: MACH ā 1 Ā BEND ā 1 Ā ENG APPR. TWO PLACE DECIMAL ā .01 THREE PLACE DECIMAL ā .001 MFG APPR. PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF MacroAir TECHNOLOGIES.
Installation – Safety Cable 1 Wrap the Safety Cable 2 Secure the Safety Cable Clamps □□ Secure two (2) safety cable clamps around the wire. Pull the cable taut and tighten both nuts using a 10mm wrench. WARNING: DO NOT PUT TOO MUCH TENSION ON THE SAFETY CABLE. THERE NEEDS TO BE A SMALL AMOUNT OF SLACK PRESENT IN THE SAFETY CABLE FOR PROPER FUNCTIONING. AVOID SHARP EDGES. □□ Wrap the safety cable around the I-beam.
Installation – Guy Wires 1 2 Secure the Guy Wires □□ Secure the four (4) guy wires to the attachment points on the frame. Secure the Guy Wires to the Building □□ Secure the four (4) guy wires to the building structure so that the guy wires are at a 45 degree angle from the drop and 90 degrees from each other. Tighten both nuts on each cable clamp using a 3/8” wrench. 45° 90° NOTE: GUY WIRES NEED TO BE SECURELY MOUNTED TO THE BUILDING.
Installation – Guy Wires 5 Insert the Guy Wire Band 7 Repeat Step 6 □□ Insert the guy wire band through the top eyelet of each of the four (4) turnbuckles. 6 Pull the Cords through the Cable Lock □□ Pull one of the ends of the cord through one of the holes on the cable lock and then pull the end into the groove to lock it. Use pliers to properly secure the cord in the groove of the cable lock. □□ Repeat step 6 for the second end of the cord using the opposite hole and groove on the cable lock.
Installation – Blades 1 2 Apply the Provided Lubricant □□ Apply the provided lubricant in 4 spots on the top and bottom of each strut. Each line of lubricant should be in the groove, approximately 1”-1.5” long and spaced as indicated in the picture. Slide the Blades onto the Blade Struts □□ Slide the blades onto the blade struts and align the holes in the blade and the blade struts. (THE LUBRICANT SHOULD REACH THE TOP OF THE GROOVE.
Installation: Electrical MOTOR CABLES AND INCOMING POWER MUST NEVER BE RUN IN THE SAME CONDUIT. FAILURE TO INSTALL PER COMMERCIAL ELECTRIC INSTRUCTIONS, INCLUDING WIRING, MAY BE HAZARDOUS, CAUSE PREMATURE FAILURE, AND VOID THE MANUFACTURER’S WARRANTY.
Installation: Electrical 1 2 Feed the Cable through the Frame □□ Feed one end of the 50’ cable to the motor through the top of the frame and plug it into the receptacle on the frame. Attach motor cable to VFD □□ Attach the other end of the 50’ cable to the receptacle on the VFD whip. FAN SPEED NEMA 4X/IP65 3 FAN SPEED NEMA 4X/IP65 Plug the VFD in □□ Plug the cable to the incoming power into an electrical outlet. 17 HOMEDEPOT.COM Please contact 1-877-527-0313 for further assistance.
Operation 1 FAN SPEED Turn the VFD on 2 Select forward direction for cooling or reverse for destratification (heating) NEMA 4X/IP65 3 Adjust the speed dial to control how fast the fan rotates NEMA 4X/IP65 FAN SPEED 18
Maintenance – Care and Cleaning Guy Wire Check (if applicable): Checking a fan’s guy wires for tension and inspecting for frayed sections could mitigate a problem before it occurs. The guy wires should be under enough tension to prevent any movement in the motor unit or the extension tube. If the motor can be moved by pushing on it, the guy wires need to be tightened. Fan owners should confirm that the guy wires are not wrapped around any sharp edges.
Troubleshooting Please refer to the table below if you experience issues with the fan operation. Symptoms Possible Solution The fan is not turning and the lights on the VFD are lit. Unplug the VFD from the wall for 30 seconds and plug it back in. Ensure that the VFD is properly connected to the motor. The fan is not turning and the lights on the VFD are NOT lit. Confirm the VFD is plugged into the wall and confirm that there is power coming from the building. The fan is making a loud “clicking” noise.
Service Parts MODEL TYPE FAN SPEED N M D H K E NEMA 4X/IP65 A B,C I, J L F O G Part Description Quantity Part Description Quantity A Complete Power Unit 1 I Retainer Links 1 B 15’ Diameter Blade (78 ¾”) 1 J Retainer Links Set of 5 1 C 15’ Diameter Blade Set of 5 (78 ¾”) 1 K Mount Bolt Kit 1 D VFD 1 L Blade Bolt Kit 1 E Extension 1 M Guy Wire Kit 1 F Blade Strut 5 N Safety Cable Kit 1 G 50’ Motor Cable 1 O End cap 1 H Mount 1 21 HOMEDEPOT.
Questions, problems, missing parts? Before returning to the store, call Commercial Electric Customer Service 8 a.m. - 7 p.m., EST, Monday-Friday, 9 a.m. - 6 p.m., EST, Saturday 1-877-527-0313 HOMEDEPOT.COM Retain this manual for future use.