Connecting the wires
□ Place the wire connector (B) on opposite sides of the main low voltage cable (sold separately) from the transformer (sold separately) where the
fixture will be located.
□ Align and fit the main low voltage cable horizontally over the slot of the wire connector (B).
□ Press the wire connector (B) together until it is locked around the main low voltage cable. The pre-set prongs will pierce the cable insulation and
establish contact with the electrical wire inside.
□ Once the wire connector (B) is in place, it is recommended to wrap it with electrical tape (sold separately).
□ After all fixtures are installed, turn on the transformer.
: The wire connector (B) contacts have sharp edges for
piercing the main low voltage cable. To avoid injury, do not touch the
metal contacts.
: The wire from low voltage power unit should be
12-16 AWG type underground low Energy Circuit Cable.
:
□ Protect the wiring by routing it in close proximity to the light
fitting, or next to a building structure such as a house or a
deck.
□ The landscape wire and connector can also be hidden under
stone or buried under grass at a maximum depth of 6 in.
(15.24 cm).
□ Do not install the fixture within 10 ft. of a pool, spa, or fountain.