Re-installing the power terminal access panel
IP-RN 8000 Installation & Commissioning Guide 205
Re-installing the power terminal access panel
This procedure explains how to re-install the power terminal access panel.
Requirements:
5/32 tamper-resistant screw driver
Thread tapping kit with 1/4-20 thread bit at 3/4 inch depth
To reinstall the power terminal access panel:
1. Open the front door.
See Opening the door
on page 198.
2. Locate the power terminal access panel area on the cabinet.
3. Retrieve the access panel and the 11 tamper-proof screws and rubber washers that you set aside when
removing the panel.
4. Examine the inside edge of the access panel to ensure the access panel is undamaged.
The gasket on the inside edge must be intact to ensure a proper seal.
5. Position the access panel and start all screws by hand.
Be sure to thread the rubber sealing washer on the screw shank before inserting it into the access panel
screw hole.
WARNING
Screws should be started by hand. It is possible to damage the
thread in the cabinet if you use a hand tool or a power tool.
Damaged threads must be repaired or the cabinet will be
improperly sealed and the IP-RN 8000 can be damaged. Use a
thread tapping set to fixed damaged threads.
Power terminal access panel
Front view, door open