This procedure explains how to install a Base Input Output/System Controller (BIO/SC) module.
Be sure you have read and understood Understanding the module installation process
on page 104 before
continuing.
Requirements
ESD wrist strap
Slotted screwdriver
Procedure
1. Identify the slot in which you will install the BIO/SC module.
The primary BIO/SC installs in slot 3. The redundant BIO/SC installs in slot 7.
See Understanding module slot numbering
on page 11 for more information.
WRIST
STRAP
Wear an ESD strap and plug it into the ESD jack in the AIU when
handling modules or equipment damage can occur. See Figure 9
on page 18.
CAUTION
Ensure that you install the BIO/SC module into the proper slot
(either slot 3 or slot 7). Installation into a slot reserved for a
different module type can cause equipment damage.