User Manual

Connecting the RM to the PA with the RF cable
IP-RN 8000 Installation & Commissioning Guide 111
Connecting the RM to the PA with the RF cable
The transmit signal generated in the RM is sent to the PA for amplification before being transmitted. This
procedure explains how to connect the RF port on the RM to the RF port on the PA module using an external
cable provided by Airvana for the sector.
Be sure you have read and understood Understanding the module installation process
on page 104 before
continuing.
Requirements
ESD wrist strap
Slotted screwdriver
Procedure
1. Retrieve the RF cable for the sector.
The cable is shipped with the modules and is labeled with its part number: 600334.
2. Examine the cable to determine which end is connected to the RM and which is connected to the PA.
The cable has a natural curve to it that makes it easy to install because it makes both connectors face the
same way. However, you have to be sure the right cable ends are connected to the RM and to the PA. So,
hold the cable in place and compare the cable connectors to the connectors on the RM and PA modules.
If the connectors do not fit, reverse the cable 180 degrees and the connectors should fit.
WRIST
STRAP
Wear an ESD strap and plug it into the ESD jack in the AIU when
performing this procedure or equipment damage can occur. See
Figure 9
on page 18.