User Manual

Understanding warnings and cautions
IP-RN 8000 Installation & Commissioning Guide 87
Understanding warnings and cautions
This section contains warnings and cautions that apply to all procedures in this chapter.
Be sure you have read and understood Understanding the antenna installation process
on page 86 before
continuing.
Understanding the pre-assembled Rox System
The Rox System cabinet seal typically ships pre-assembled and is ready to install. The pre-assembled Rox
System cabinet seal supports:
Three radio sectors
Each radio sector has two RF antenna cables. One cable carries two signals, a transmit signal and a
receive signal. The second contains a single receive antenna cable.
Two GPS antenna cables — one primary GPS antenna and one redundant GPS antenna
WARNING
Do not perform any of these procedures when there is a
possibility of lightning strikes. Death or injury could occur if
lightning strikes during installation.
WARNING
Upon installation, this product is required to comply with the
requirements of Federal Communications Commission 47CFR
1.1310, Radiofrequency radiation exposure limits. Care must be
taken by the installer to insure that the antenna chosen along with
its installation position and orientation does not violate these
limits.
WARNING
Do not perform any of these procedures if the IP-RN 8000 has not
been properly grounded.
WRIST
STRAP
Wear an ESD strap and connect the strap to the ESD jack in the
Antenna Interface Unit when performing any installation
procedure. See Understanding the Antenna Interface Unit module
on page 17.