Connecting the power supply
IP-RN 8000 Installation & Commissioning Guide 65
5. Thread the backhaul cable through its conduit and attach the backhaul conduit to backhaul cable port on
the right side cable access panel. To locate the backhaul cable port, see Right side view with the front
door open on page 5.
6. Reach through the power terminal access panel area and grip the backhaul cable(s).
7. Pull five feet of backhaul cable(s) forward to the front of the cabinet.
8. Re-install the right side cable access panel. See Re-installing the right side cable access panel
on
page 207.
This procedure is complete. Go to Connecting the power supply
on page 65.
Connecting the power supply
This procedure explains how to connect the power wires to the power terminals.
You can optionally connect a third wire ground if your site planner specifies it. See Understanding surge
protection and grounding on page 33.
Be sure you have read and understood Understanding the cabinet installation process
on page 50 before
continuing.
Requirements
3/16 inch hex wrench
NOTE
The backhaul cable could consist of one to four separate cables.
See Understanding the backhaul installation process
on page 74
NOTE
This procedure assumes the power cables are already threaded
inside the cabinet. See Routing power and backhaul cables into
cabinet and closing right side access panel on page 64.
WARNING
Power supply must meet IP-RN 8000 specifications. See Power
specifications on page 193.