Installation Guide
Appendix B Installation troubleshooting
ONECELL
®
Hardware Installation, Release 5.5 B-3
D
R
A
F
T
TIMING LED Green, solid Power On, timing None
Amber, solid Self-test failure Replace Baseband Controller
Amber, blinking No timing Check GPS antenna connection feed
Off Firmware upgrade from
DMS
None
Red, solid* Error in system
GPS module down
Software/Hardware issues
Replace Baseband Controller Module
CORE LED Green, solid Power On
Connection to MME
None
Amber, solid Self-test failure Replace Baseband Controller
Amber, blinking No connection to MME
IPsec is up
• Check the MME configuration on the BC
• Check if MME is reachable
Off Firmware upgrade from
DMS
None
Red, blinking Internet connection
IPsec down
• Check if Security Gateway is reachable
• Check security credentials
Red, solid* No Internet
Interface hardware issues
Replace Baseband Controller Module
* Note: When all of the LEDs are solid red, there is a BC hardware failure.
LED Display Pattern Indicates Action to Take