Installation Guide

Appendix B Installation troubleshooting
ONECELL
®
Hardware Installation, Release 5.5 B-5
D
R
A
F
T
The following table shows:
Display pattern for each LED
What the pattern indicates
Action to take, if any, to resolve the issue
LED Display Pattern Indicates Action to Take
RADIO 1
RADIO 2
RADIO 3
RADIO 4
Green, solid Power On, transmitting None
Amber, solid
RFTxState OFF
No Controller Assigned
No Timing
Check 1588 VLAN configuration
Verify that the Radio Point is in
STANDBY because more than 32 RPs
are connected
Red, solid
No connection to Controller
HW error
Low Power
Hardware error – replace Radio Point
Green, blinking Firmware upgrade None
Amber, blinking RF module Self-Test Failure Replace Radio Module
Eth 1 Green, solid Power On, PoE++ power None
Amber, solid Link up, no power Check that the Ethernet cable is
connected to the
Radio Point
Green, blinking PoE+ power None
Amber, blinking Platform Self-Test Failure Replace Radio Point
Red, solid Ethernet port error
Connect the Ethernet cable between the
Baseband Controller and Radio Point
Replace Radio Point
Eth 2 Green, solid Power On, PoE++ power None
Amber, solid Link up, no power Check that the Ethernet cable is
connected to the Radio Point
Green, blinking PoE+ power None
Amber, blinking Platform Self-Test Failure Replace
Radio Point
Red, solid Ethernet port error
Connect the Ethernet cable between the
Baseband Controller and Radio Point
Replace Radio Point
* Note: When all of the LEDs are solid red, there is an RP hardware failure.