Users Manual Part 2
Appendix B Installation troubleshooting
ONECELL
®
Hardware Installation, Release 5.5 B-5
D
R
A
F
T
The following table shows:
• Display pattern for each LED
• What the pattern indicates
• Action to take, if any, to resolve the issue
LED Display Pattern Indicates Action to Take
RADIO 1
RADIO 2
RADIO 3
RADIO 4
Green, solid Power On, transmitting None
Amber, solid
• RFTxState OFF
• No Controller Assigned
• No Timing
• Check 1588 VLAN configuration
• Verify that the Radio Point is in
STANDBY because more than 32 RPs
are connected
Red, solid
• No connection to Controller
• HW error
• Low Power
Hardware error – replace Radio Point
Green, blinking Firmware upgrade None
Amber, blinking RF module Self-Test Failure Replace Radio Module
Eth 1 Green, solid Power On, PoE++ power None
Amber, solid Link up, no power Check that the Ethernet cable is
connected to the
Radio Point
Green, blinking PoE+ power None
Amber, blinking Platform Self-Test Failure Replace Radio Point
Red, solid Ethernet port error
• Connect the Ethernet cable between the
Baseband Controller and Radio Point
• Replace Radio Point
Eth 2 Green, solid Power On, PoE++ power None
Amber, solid Link up, no power Check that the Ethernet cable is
connected to the Radio Point
Green, blinking PoE+ power None
Amber, blinking Platform Self-Test Failure Replace
Radio Point
Red, solid Ethernet port error
• Connect the Ethernet cable between the
Baseband Controller and Radio Point
• Replace Radio Point
* Note: When all of the LEDs are solid red, there is an RP hardware failure.