Users Manual Part 1

Chapter 5 RP5100r installation
5-3 M0304AC 5.5.01 July 2021
D
R
A
F
T
RJ45, IP67 connector for CAT 5E
Ethernet surge protector, as required by local code (for example, DTK-MRJPOEX
or DTK-MRJPOES)
NOTE
If the MR port is connected to a switch that does not provide IEEE802.3bt, type-4
PoE power, the SR port can be used to provide power with a PoE++ injector. In this
case, the installer needs to provide a CAT 5E – MPN 17-10044 connector (https://
www.conec.com/catalog/en/rj45-stecker-set.html) to connect the RJ45 to the SR
port. For more information, see ONECELL
®
Network Planning Guide, v5.5
(M0304AF).
Figure 5-2. Hardware provided by the systems integrator
Mounting the Radio Point (RP) on a wall requires the following hardware provided by
the system integrator:
Four molly screws capable – 50 lb (23 kg) minimum rating
NOTE
Once the Radio Point is installed and the powered on, it may take up to 20 minutes
for the frequency to stabilize and lock.
Before connecting the Ethernet cables to the RP, terminate the RP end of the Ethernet
cable with the RJ45, IP67 connector.