Users Manual Part 2

Chapter A Safety
ONECELL
®
Hardware Installation, Release 5.5 A-3
D
R
A
F
T
Table A-1 includes values for one Radio Point (RP5000 series) and four Radio Points
per chassis.
Table A-1. RF exposure for ONECELL at maximum power internal antennas for RP5000
series
Parameter
RPM-A5A11-
B66
RPM-A5A11-
B02
RPM-I5A11-
B01
RPM-I5A11-
B03
RPM-I5A11-
B07
Tx Power (dBm) per
antenna
24.13 24.23 24.25 24.00 24.70
Tx Loss (dB) 0 0 0 0 0
Tx Antenna Gain (dBi) 4 4 4 4 4
Transmitter Duty Cycle % 100 100 100 100 100
Number of Antennas
(MIMO)
2 2 2 2 2
Contribution due to
multiple antennas (dB)
3.0103 3.0103 3.0103 3.0103 3.0103
Derived Total EIRP (dBW) 1.140 1.240 1.260 1.010 1.710
Bands 66 2 1 3 7
Frequency Range (MHz) 2110-2200 1930-1990 2110-2170 1805-1880 2620-2690
Point Source Total EIRP
(watts)
1.300 1.331 1.337 1.262 1.483
Power Density (W/m2) @
20 cm
2.587 2.647 2.569 2.510 2.950
1. For persons with implants, the maximum calculated distance of 30cm. This applies to any combination of up to
four radio modules in Bands 1,3 and 7.
2. For general public and workers, a measured distance of 5mm was determined. This applies to any combination
of up to four radio modules in Bands 1,3 and 7.
For general public and workers, a calculated distance of 20cm was determined. This applies to any combination of
up to four radio modules in Bands 2 and 66.
Parameter
RPM-I5A11-
B17
RPM-A5A11-
B12
RPM-A5A11-
B14
RPM-A5A11-
B05
RPM-A5A11-
B30
Tx Power (dBm) per
antenna
21.70 21.88 21.45 21.58 20.99
Tx Loss (dB) 0 0 0 0 0
Tx Antenna Gain (dBi) 4 4 4 2 5