Specifications

Appendix D Field Replaceable Units
OneCell
®
Hardware Installation, Release 4.5 D-3
D
R
A
F
T
Off-site activities
Before replacing the BC module, import a new EDF file to the DMS. This file
contains the BC MAC address and HeMs password specific to the new BC.
1 Access the FTP location on DMS using ftp protocol, port 2100.
2 Upload the EDF file to /appdata/dms/import/factory.
3 Access the DMS Network console from a supported Web Browser.
NOTE: The DMS GUI supports Internet Explorer versions 9, 10 and 11 and
Chrome version 36 Web browsers, and a screen resolution of 1024 x 768 and
higher.
4 Enter the IP address for the Network Management portal.
http://<IP Address DMS server>/networkconsole
The Sign In dialog box displays.
Configuration details for WebGUI commissioning
Note: These parameters are derived from the failed
unit being replaced.
Ethernet cable
Note: Required for connecting the laptop to the
OneCell Baseband Controller Management port
DMS FTP IP address
Prerequisite