Pre-Installation Notes:
Connect the local PC to the controller using the Ethernet crossover cable.
Before installing antennas equipped with actuators to the tower, each actuator
should be connected to the controller and tested for proper operation.
Andrew recommends that you register online to receive notif
cations for up-
dates made to the software and antenna def nition f le. It is also recom-
mended that the Commscope web site be checked every 30 days for updated
software/documentation.
If using the 48V power connection, ensure wires are properly connected.
Reversal of wire connection can cause permanent damage to the
controller.
2. Controller program startup and device scan
Click on Go (or press Enter on the keyboard) to access the ATC200-1000
Controller main interface screen (below).
2. Device search. Click on Find Devices. See screen above.
Select number of known devices on Max devices drop down list, bel
ow.
Click on Start Scan, as seen on screen below
.
After the scan is complete, click on Close.
If an antenna/actuator has been removed or added to the site, a new
scan is required.
1. Controller access.
Refer to Bulletin 639561 for instructions about using the IP Conf g Tool to
reconf gure the local PC/laptop’s IP address for access to the ATC200-
1000’s main operating interface.
Type the controller’s IP address into Internet browser URL window. The
factory default IP address is 192.168.255.141. See screen below.