Users Manual Part 1

CommScope Era
CAP M 4/70/80 M0201AYA_uc
Page 16 © October 2019 CommScope, Inc.
Installing CAP Ms
INSTALLING CAP MS
The following sections guide you through the installation of a CAP M. Pay attention to all cautions and follow
the steps in the order presented.
CAP M APs require the use of RFD Card PN 7633229-01 or 7633229-02 or higher.
CAP M Installation and Cascade Rules
When cascading a Secondary CAP M or an external Ethernet device such as WiFi or an IP camera, you must
observe the following rules.
I
n a cascade, the CAP M connected directly to the Classic CAN or TEN is the Primary CAP M, and the CAP M
that connects to the Primary CAP M is the Secondary CAP M.
You connect
CAP Ms to an OPT Card in the Classic CAN or TEN.
Each OPT
Card has four 10 Gbps ports (labeled 1 - 4) for fiber connections.
You can connect
up to 4 CAP Ms per OPT Card for a total of 16 Primary CAP Ms, per Classic CAN or
TEN.
You can connect
one Secondary CAP M to each Primary CAP M for a total of eight CAP Ms per OPT
Card, which 32 total CAP Ms per Classic CAN or TEN.
The total 320 MHz RF bandwidth is shared between the two cascaded units, but can be sh
ared unevenly;
that is, with more bandwidth going to either the Primary or Secondary CAP M—either CAP M can
tran
smit all the 320 MHz RF bandwidth or any subset of it.
The Primary and
Secondary CAP Ms power up as soon as power is applied to them. In a cascade, the GUI
discovers and readies the Primary CAP M for RF first, and then the Secondary CAP M will be discovered
and readied for RF. For
information on the Power LED behavior, see "Power the CAP M” on page 59.
SMF
or MMF connects the CAP M via its Optical Port 1 to the OPT Card.
Whe
n cascading a Secondary CAP M or an external Ethernet device such as WiFi or an IP camera, you
must observe the following rules.
To c
ascade two CAP Ms, use a fiber-optic cable.
SM
F or MMF connects the Secondary CAP M via its Optical Port 1 to the Primary CAP M via its Optical
Port 2.
You can connect
the following to the Primary CAP M
a Secondary CAP M
an Ethernet device
both a Secondary CAP M and an Ethernet device.
To
add a Secondary AP, you must add an Optical OCTIS kit to the Primary CAP M, see "OCTIS Kits” on
page 9.
To
add an Ethernet device, you must add an RJ45 OCTIS kit to the Primary CAP M, see "OCTIS Kits” on
page 9.