Installation Guide

Table Of Contents
Table 2. Function of the CAP M Connectors and LED
REF # Label Description Function
1 A RJ45
Auxiliary p
ort
Connects to external Ethernet devices such as WiFi and IP cameras. Cabling is via the appropriate
CAT cable for the protocol; this model supports a 1000 BASE-T and 802.3at Class 3 Power over
Cat6A Ethernet connection. Maximum attached cable length is 3 meters (9.8 feet). For
information on the Auxiliary port in cascades, see "CAP M Installation and Cascade Rules” on
page 17. Port A ships with factory-installed EMI/weatherproof plug and must remain plugged if
not in use. (Graphic shows the port populated with an
OCTIS Ethernet connector PN 7760652
which must be ordered separately—see "OCTIS Kits” on page 9.)
2 2 Optical Port 2 If the CAP M is functioning as a Primary CAP M in a cascade, Optical Port 2 connects to Optical Port
1
of the Secondary CAP M via the Optical OCTIS Kit (PN 7770612), which ships with the unit, to
p
rovide the main signal interface. Optical transport occurs over Single Mode Fiber (SMF) or Multi
Mode Fiber (MMF). Port 2 ships with factory-installed EMI/weatherproof plug and must remain
plugged if not in use. Graphic shows the OCTIS connector in blue; one Optical OCTIS Kit ships with
each Fiber CAP M (see "OCTIS Kits” on page 9).
3 1 Optical Port 1 Connects to a Classic CAN or TEN (possibly through a local Hybrid Fiber Junction Box) and provides
the mai
n signal interface; if Secondary CAP M in a cascade, Optical Port 1 connects to Optical Port
2
of the Primary CAP M. Optical transport occurs over Single Mode Fiber (SMF) or Multi Mode
Fiber (MMF). Uses the Optical OCTIS Kit (PN 7770612), which ships with the unit. Port 1 ships with
a dust cap that can be discarded upon unit installation. Graphic shows the OCTIS connector in blue.
4 Unlabeled Power LED See "Power the CAP M” on page 60.
5a ANT or ANT1
4.3-10 RF
con
nector
Transmits and receiving signals to and from distrib
uted antennas. For models with two antennas,
connects to two separate external antennas or to two ports on a cross-polarized dual antenna via
50 coaxial cable. Each connector supports two RF bands; see "Connect the CAP M to an RF
Antenna” on page 52. This RF port can be connected directly to an
antenna (using RF jumper
cables) or through splitters, allowing
additional antennas to be fed by the CAP M.
5b ANT2
6 Unlabeled Grounding
bolts
Connects the CAP M to an approved earth-ground source.
7 Mains Power
connector
(Vac or Vdc)
Connects to any of the following (graphic shows the port populated):
Vac—Main power
Vdc—Remote DC power supply or a Hybrid Fiber Junction Box.
M0201AJE_uc CommScope Era
Medium Power Carrier Access Point Installation Guide
© February 2020 CommScope, Inc. Page 7
CAP M Overview